Electrical connections:
The compressor is equipped with a power cable and
an earthing-pin plug for connection to any 230 V ~ 50
Hz earthing-contact socket outlet with a 16 A fuse.
Long supply lines, extensions, cable reels and similar
cause voltage dips and may prevent the motor from
starting. Sluggishness makes starting difficult at low
temperatures under freezing point (0°C).
Explanation of the compressed air fittings
1 Pressure switch
2 Safety valve
3 Pressure gauge (to indicate the vessel pressure)
4 On/Off switch
4

Maintenance and cleaning

G Condensation water
Let out the condensation water daily by opening
the drain valve (bottom of the pressure vessel).
G Safety valve
The safety valve is set to themaximum pressure
of the pressure vessel. It is prohibited to adjust
the safety valve or to remove its lead seal.
To ensure that the safety valve works properly in
the event of an incident you should actuate it
from time to time. To do so, turn the knurled
screw anticlockwise until you can hear
compressed air being blown out. Then turn the
knurled screw clockwise as far as the stop and
tighten by hand.
G Regular oil level checks
The level of oil has to be visible in the sight-glass
between the red check-point mark and the upper
edge of the sight-glass.
Changing the oil:
Recommended grade SAE 15W/40 or equivalent.
The first oil change should be carried out after
12
22.01.2007
10:08 Uhr
Seite 12
100 operating hours. Thereafter you should
drain the oil and replace it with new oil at
intervals of 500 operating hours.
G Changing the oil
Switch off the motor and pull the power plug out
of the socket-outlet. After letting off any air
pressure you can remove the oil drain plug from
the compressor pump by unscrewing. To prevent
the oil escaping out of control, hold a small piece
of metal guttering underneath the drain plug to
direct the oil into a container.If any oil still
remains inside, tilt the compressor a little.
Take the old oil to an official old oil disposal
station.
When the old oil has run out, screw the oil drain
plug/sight-glass back in place.
Use a screwdriver to remove the cap of the oil
filler plug and fill in oil until the level of oil in the
sight-glass reaches the red mark.
Then put the cap back on the oil filler plug.
5
1 Filter
2 Oil filter plug
3 Oil drain plug/sight-glass
G Cleaning the intake filter
The intake filter prevents dust and dirt being
drawn into the machine. This filter has to be
cleaned at intervals of no longer than 300
operating hours. A clogged intake filter has a
considerable negative effect on the compressorʼs
power.
The filter can be removed as shown in Figure 3.
Wash out the filter with petroleum ether and
reinsert.
Caution! Wait until the compressor has
cooled completely!
Risk of burns!