Herunterladen Diese Seite drucken
Vimar Well-contact Plus 01500.2 Handbuch
Vimar Well-contact Plus 01500.2 Handbuch

Vimar Well-contact Plus 01500.2 Handbuch

Werbung

Well-contact Plus
01500.2 - 01501.2
01500.2 - Alimentatore con uscita Bus 30 Vdc 320 mA, uscita ausiliaria 30 Vdc,
alimentazione 120-240 V~ 50/60 Hz, con bobina di disaccoppiamento, standard
KNX, installazione su guida DIN (60715 TH35), occupa 4 moduli da 17,5 mm.
01501.2 - Alimentatore con uscita Bus 30 Vdc 640 mA, uscita ausiliaria 30 Vdc,
alimentazione 120-240 V~ 50/60 Hz, con bobina di disaccoppiamento, standard
KNX, installazione su guida DIN (60715 TH35), occupa 4 moduli da 17,5 mm.
Alimentatore per sistemi bus provvisto di bobina di disaccoppiamento.Ogni linea bus necessita di
almeno un alimentatore; qualora la tensione sul bus risulti inferiore ai 21 V è necessario installare
un secondo alimentatore che disti almeno 200 m dal primo. Nel caso in cui vi siano 30 o più
dispositivi bus installati vicini fra loro (ad esempio in 10 -15 m di cavo o all'interno del mede-
simo quadro elettrico), è consigliabile installare l'alimentatore in prossimità di questi dispositivi.
La distanza massima tra l'alimentatore e il dispositivo più lontano non deve superare i 350 m.
L'alimentatore è inoltre provvisto di un'uscita ausiliaria che fornisce una tensione di 30 V d.c. che
può essere utilizzata per il collegamento di un'ulteriore linea bus mediante bobina di disaccop-
piamento. L'alimentatore è auto-protetto dai cortocircuiti (grazie ad un regolatore di tensione e di
corrente) e garantisce l'alimentazione anche nel caso di brevi intervalli di mancanza rete purché
questi non superino i 200 ms. Si consiglia di dedicare sempre un interruttore di protezione per il
circuito elettrico di alimentazione del dispositivo 01500.2-01501.2.
CARATTERISTICHE.
• Tensione di alimentazione: 120-240 V~ 50/60 Hz .
• Tensione di uscita BUS KNX: 30 V d.c. (SELV) con bobina di disaccoppiamento.
• Tensione di uscita ausiliaria: 30 V d.c. (SELV).
• Temperatura di funzionamento: -5 °C - + 45 °C (uso interno).
• Grado di protezione: IP40.
• 4 moduli da 17,5 mm.
01500.2
• Consumo:
- a 120 V~: 185 mA
- a 240 V~: 120 mA
• Potenza dissipata: 3 W
• Corrente max in uscita I
: 320 mA (I
MAX
KNX
• Corrente di cortocircuito: 0,8 A
01501.2
• Consumo:
- a 120 V~: 360 mA
- a 240 V~: 220 mA
• Potenza dissipata: 4,5 W
• Corrente max in uscita I
: 640 mA (I
MAX
KNX
• Corrente di cortocircuito: 1,4 A
FUNZIONAMENTO.
Alimentare il dispositivo dopo averlo connesso; il led si illumina di colore verde e questo indica
che il dispositivo funziona correttamente.
L'alimentatore viene principalmente utilizzato per fornire alimentazione a:
– linee fino a 32 dispositivi bus per l'art. 01500.2 e fino a 64 dispositivi bus per l'art. 01501.2
(es. palazzi ad uso ufficio, centri commerciali, palazzine ad uso residenziale);
- linee con un numero limitato di dispositivi e alimentazione contemporanea di una linea principale
e di una linea secondaria (utilizzando la tensione ausiliaria di 30 V d.c. in combinazione con
una bobina di alimentazione).
N.B. Per effettuare il "Reset" dell'alimentatore, rimuovere i morsetti di connessione al bus e, dopo
circa 20 secondi, reinserirli al loro posto.
La linea bus si collega nuovamente all'alimentazione e i dispositivi bus ritornano nelle condizioni
iniziali predefinite.
SEGNALAZIONI DEI LED
L'alimentatore è provvisto di un led bicolore verde/rosso che consente di visualizzare il funziona-
mento normale, sovraccarico e cortocircuito. Nel dispositivo i valori della corrente di sovraccarico
e di cortocircuito si applicano alla corrente totale I
• Led verde = Funzionamento normale (I≤I
• Led rosso = Sovraccarico (I>I
)
MAX
• Led spento = Assenza tensione di rete
REGOLE DI INSTALLAZIONE.
L'installazione deve essere effettuata da personale qualificato con l'osservanza delle disposizioni
regolanti l'installazione del materiale elettrico in vigore nel paese dove i prodotti sono installati.
Garantire delle distanze minime attorno all'apparecchio in modo che vi sia una sufficiente ventila-
zione. L'apparecchio non deve essere sottoposto a stillicidio o a spruzzi d'acqua.
ATTENZIONE: Per evitare di ferirsi, l'apparecchio deve essere assicurato alla parete secondo
quanto indicato nelle istruzioni di installazione.
A monte dell'alimentatore, deve essere installato un interruttore di tipo bipolare facilmente acces-
sibile con separazione tra i contatti di almeno 3 mm.
CONFORMITÀ NORMATIVA.
Direttiva BT. Direttiva EMC. Norme EN 60065, EN 50491.
Regolamento REACh (UE) n. 1907/2006 – art.33. Il prodotto potrebbe contenere tracce di piombo.
RAEE - Informazione agli utilizzatori
Il simbolo del cassonetto barrato riportato sull'apparecchiatura o sulla sua confezione indica che il prodotto alla fine della
propria vita utile deve essere raccolto separatamente dagli altri rifiuti. L'utente dovrà, pertanto, conferire l'apparecchiatura
giunta a fine vita agli idonei centri comunali di raccolta differenziata dei rifiuti elettrotecnici ed elettronici. In alternativa alla
gestione autonoma, è possibile consegnare gratuitamente l'apparecchiatura che si desidera smaltire al distributore, al mo-
mento dell'acquisto di una nuova apparecchiatura di tipo equivalente. Presso i distributori di prodotti elettronici con superfi-
cie di vendita di almeno 400 m
è inoltre possibile consegnare gratuitamente, senza obbligo di acquisto, i prodotti elettronici
2
da smaltire con dimensioni inferiori a 25 cm. L'adeguata raccolta differenziata per l'avvio successivo dell'apparecchiatura
dismessa al riciclaggio, al trattamento e allo smaltimento ambientalmente compatibile contribuisce ad evitare possibili effetti
negativi sull'ambiente e sulla salute e favorisce il reimpiego e/o riciclo dei materiali di cui è composta l'apparecchiatura.
49400979B0 01 1909
+ I
)
AUX
+ I
)
AUX
= I
+ I
.
MAX
KNX
AUX
)
MAX
01500.2 - Power supply unit with bus output of 30 Vd.c. SELV 320 mA, auxiliary
output 30 Vd.c., power supply 120-240 V~ 50/60 Hz, with decoupling coil, KNX
standard, installation on DIN rail (60715 TH35), occupies 4 modules of 17.5 mm.
01501.2 - Power supply unit with bus output of 30 Vd.c. SELV 640 mA, auxiliary
output 30 Vd.c. SELV, power supply 120-240 V~ 50/60 Hz, with decoupling coil,
KNX standard, installation on DIN rail (60715 TH35), occupies 4 modules of
17.5 mm.
Power supply unit for bus systems equipped with decoupling coil.
Each bus line needs at least one power unit; if the voltage on the bus is less than 21 V it is
necessary to install a second power unit at a distance of at least 200 m from the first one. If there
are 30 or more bus devices installed near to each other (for instance in 10-15 m of cable or in the
same electric panel), it is advisable to install the power unit near to these devices. The maximum
distance between the power unit and the furthest device must not exceed 350 m. The power
unit is moreover equipped with an auxiliary output that supplies a voltage of 30 V d.c. that can
be used to connect an additional bus line via a decoupling coil. The power unit is self-protected
against short circuits (thanks to a voltage and current regulator) and ensures a power supply even
in the event of brief mains failures provided they do not exceed 200 ms. It is recommended to
always have a safety switch for the electric power supply circuit of the device 01500.2-01501.2.
CHARACTERISTICS.
• Supply voltage: 120-240 V~ 50/60 Hz.
• KNX BUS output voltage: 30 V d.c. (SELV) with decoupling coil.
• AUX output voltage: 30 V d.c. (SELV).
• Operating temperature: -5 °C - +45 °C (inside).
• Protection rating: IP40.
• 4 modules of 17.5 mm.
01500.2
• Consumption:
- 120 V~: 185 mA
- 240 V~: 120 mA
• Dissipated power: 3 W
• Total max output current I
: 320 mA (I
MAX
• Short-circuit current: 0,8 A
01501.2
• Consumption:
- 120 V~: 360 mA
- 240 V~: 220 mA
• Dissipated power: 4,5 W
• Total max output current I
: 640 mA (I
MAX
• Short-circuit current: 1,4 A
OPERATION.
Power the device after connecting it; the led lights green color and this indicates that the device
is working correctly.
The power unit is mainly used to supply power to:
– lines with up to 32 bus devices for art. 01500.2 and to 64 bus devices for art. 01501.2 (e.g.,
office blocks, shopping malls, blocks of flats);
- lines with a limited number of devices and simultaneous power supply of a main line and a
secondary line (using the auxiliary voltage of 30 V d.c. in combination with a power supply coil).
To "Reset" the power unit, remove the bus connection terminals and, after approximately 20
seconds, put them back in place.
If the line is disconnected for a long time, it is necessary to disconnect the bus connection
terminals of the power unit.
SIGNAL LED
The power supply has a two-color LED green/red displays the voltage, overload and short circuit.
In the device the values of the overload current and short-circuit is applied to the total current
I
= I
+ I
.
MAX
KNX
AUX
• Green Led = Normal operation (I≤I
)
MAX
• Red Led = Overload (I>I
)
MAX
• Led OFF = Absence of mains
INSTALLATION RULES.
Installation should be carried out by qualified personnel in compliance with the current regulations
regarding the installation of electrical equipment in the country where the products are installed.
Ensure clearance around the appliance so there is sufficient ventilation. There must be no drip-
ping or splashes of water on the appliance.
WARNING: To prevent injury, the appliance must be secured to the wall as described in the
installation instructions. Above the power supply there must be a bipolar circuit breaker that is
easily accessible with a contact gap o at least 3 mm.
REGULATORY COMPLIANCE.
LV directive. EMC directive.
Standards EN 60065, EN 50491.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be
included with other general waste at the end of its working life. The user must take the worn product to a sorted
waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free
of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m
less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment and people's health, and
encourages the re-use and/or recycling of the construction materials.
+ I
)
KNX
AUX
+ I
)
KNX
AUX
, if they measure
2
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com

Werbung

loading

Inhaltszusammenfassung für Vimar Well-contact Plus 01500.2

  • Seite 1 è composta l’apparecchiatura. Viale Vicenza, 14 36063 Marostica VI - Italy www.vimar.com 49400979B0 01 1909...
  • Seite 2 Viale Vicenza, 14 36063 Marostica VI - Italy www.vimar.com 49400979B0 01 1909...
  • Seite 3 της συσκευής, συμβάλλει στην αποφυγή αρνητικών επιπτώσεων για το περιβάλλον και την υγεία και Recyceln der Materialien, aus denen das Gerat besteht. προωθεί την επαναχρησιμοποίηση ή/και ανακύκλωση των υλικών από τα οποία αποτελείται η συσκευή. Viale Vicenza, 14 36063 Marostica VI - Italy www.vimar.com 49400979B0 01 1909...
  • Seite 4 ‫الجمع املنفصل للنفايات واألجهزة القدمية هذه، من أجل إعادة تدويرها ومعالجتها والتخلص منها بشكل متوافق بيئي ا ً، يف تجنب اآلثار السلبية املحتملة عىل البيئة وعىل الصحة كام تشجع عىل‬ .‫توسيع عملية إعادة تدوير املواد التي تتكون منها هذه األجهزة واملنتجات‬ Viale Vicenza, 14 36063 Marostica VI - Italy www.vimar.com 49400979B0 01 1909...

Diese Anleitung auch für:

Well-contact plus 01501.2