Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Leuze MA 8.1 Bedienungsanleitung

Modulare anschlusseinheit fur bcl 8/bps 8
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NOTICE
The switching output is not secured against feedback to the switching
input. If the inverted sensor output lies on pin 2, for example, erro-
neous behavior of the switching output will result.
Ä
Only use sensors without switching output on pin 2 or sensor ca-
bles without pin 2 assignment.

Technical data

Supply voltage
Current consumption, max.
Housing material
Degree of protection
Dimensions
Net weight
Connection type
Ambient temperature, operation
Ambient temperature, storage
Relative humidity (non-condensing)
Vibration
Electromagnetic compatibility
Certifications
10 ... 30 V DC
50 mA
Plastic
IP67
(Only if the connectors and caps are
screwed into place)
See
1
70 g
M12 connector, 5-pin, A-coded
0 °C ... +50 °C
-30 °C ... +80 °C
0 ... 90 %
IEC 60068-2-6, test Fc
EN 61000-6-2, EN 61000-6-3
CE, c UL US
EN
17

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ma 8-01Ma 8-02

Inhaltsverzeichnis