Herunterladen Inhalt Inhalt Diese Seite drucken

Leuze MA 8.1 Bedienungsanleitung Seite 14

Modulare anschlusseinheit fur bcl 8/bps 8
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
Electrical connection MA 8.1
2
A
M12 socket, 5-pin, A-coded
B
M12 socket, 5-pin, A-coded
C M12 connector, 5-pin, A-coded
D Possible connection point for functional earth
A – BCL/BPS 8
Pin
Signal
1
+5.2 V
2
TXD (RS 232) Data from BCL/BPS 8 to host
3
GND
4
RXD (RS 232) Data from host to BCL/BPS 8
5
SWIO
Thread
M12 socket
B – SW IN/OUT
Pin
Signal
1
VOUT
2
SWO
3
GND
4
SWI
5
FE
Thread
M12 socket
14
Description
Supply voltage BCL/BPS 8: 4.75 ... 5.5 V DC
Ground
Programmable switching input/output of the BCL/
BPS 8
Functional earth
Description
Sensor/actuator supply voltage: 10 ... 30 V DC, direct
connection to power supply unit
Switching output, max. 60 mA
Ground
Switching input, 10 ... 30 V
Functional earth