Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Elkron DC600S Anleitung

Mit weißem oder braunem trägheitssensor
Vorschau ausblenden Andere Handbücher für DC600S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation

Use as opening detector:
The detector may be installed in either of the two possible vertical positions.
The distance between the device and the magnet must not be more than 15 mm when the door is closed.
Avoid installation on metal surfaces, if possible.
Install the device as high as possible.
Use as shock/vibration detector:
The device can be installed on perfectly flat concrete or wood surfaces or on window and door frames.
When installed on windows or doors, it can also be used as an opening detector. IMPORTANT NOTE: Detection on
multilayer or mesh glass is not guaranteed because the vibrations are attenuated by the materials.
Use the following table as a reference for the selection of materials and detection parameters.
Thickness
Material
Positioning
Detection type
Detection
diameter for
different
sensitivities
Installation
1. Open the device by undoing the cover fixing screw.
2. Break the hole pattern on the base.
3. Using the base as a template for the holes, make the holes in the installation surface.
4. Insert the anchor bolts.
5. Screw the base to the anchor bolts using the flat head screws provided.
6. Fix the cover to the base and tighten the cover fixing screw.
7. Fix the magnet with screws or double-sided adhesive tape.
<
N
O
T
E
>
<
N
O
T
E
>
Do not install the device on a surface subject to frequent vibrations to prevent false alarms.
8
Door
Coverage area:
up to 1,5 m
Window glass
> 5mm
Normal or tempered
Mobile window frame
Low
2m
Medium
3m
High
4m
Window
Coverage area:
up to 2 m
Door
<40mm
Wood/steel
Door frame
Single pulse
1m
2m
3m
Window
Coverage
area: up to
2 m on
each
window
Masonry
-
Cement/concrete
On the wall near the detection point
Multiple pulse / sum of vibrations
detection
0.5m
1.5m
2m
DS80MM1L-001

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dc600s/br

Inhaltsverzeichnis