Quick Start Guide
MA48
Electronic Display
For detailed documentation please refer under
http://www.siko-global.com/p/ma48
General information
Prior to installation, including in hazard areas, read the Installation Instruc-
tion (download from the internet). It contains the safety instructions, hints
and technical data to be observed during installation. Subject to change with-
out notice.
Caution
In order to ensure reliable functioning of this product, take care to transport,
store, position and mount it appropriately. Exercise care when you operate and
maintain the device. Only properly qualified personnel is authorized to install
and operate this product.
Safety information
It is important for safety reasons that you read and understand the below
instructions before you install the system:
• Installation, connection, commissioning and maintenance shall be done by
properly qualified personnel.
• It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of
the Installation Instruction.
• It is the responsibility of the customer to ensure that the electronic display
is correctly connected and configured.
• Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.
SIKO GmbH
Weihermattenweg 2
Phone: + 49 7661 394-0
79256 Buchenbach
Fax: + 49 7661 394-388
www.siko-global.com
Service: support@siko-global.com
MA48 · Date 03.09.2019 · Art. No. 90045 · Mod. status 172/19
Mounting of the electronic display
For switchboard installation the recommended dimensions of IEC 61554 shall
be applied.
• Push the device into the panel cut-out
until the panel clips
1
housing loosely.
• Press the lateral centering
3
slightly down and push the housing into the
cut-out
1
until the panel clips
2
snap completely.
2
1
3
Electrical Installation
The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the electronic display or the connection lines!
• When mounting the system keep a maximum possible distance from lines
loaded with interference. Use screening shields or metallized housings.
• Contactor coils must be linked with spark suppression.
Connection
Strand cross section
PE tag for con-
≤2.5 mm²
nection
PIN
Designation PP/OC, OE
Designation LD, OP
1
+UB
+UB
2
A
A
3
nc
/A
4
B
B
5
nc
/B
6
I
I
7
nc
/I
8
GND
GND
9
RFS (switching to ground)
RFS (switching to ground)
10
GND
GND
PE
PE
PE
N
N (230/115 V AC); 0 V (24 V DC)
N (230/115 V AC); 0 V (24 V DC)
L
L (230/115 V AC); +UB (24 V DC)
L (230/115 V AC); +UB (24 V DC)
Technical data
Electrical data
Operating voltage
24 V DC ±20 %
hold the
2
115 V AC ±10 %
230 V AC ±10 %
Current consumption 60 mA
Additional information
at 24 V DC, without encoder