EN: Installation Instructions
Legend for Figures
1
Magnetic contact
2
Installation and connection diagram
A
Contact
B
Magnet
3
Distance diagram
A
Proximity/switch-on distance
B
Distance/switch-off clearance
C
Tolerance zone
D
Contact
E
Magnet
4
Connection
A, B, C,
Connection cable
D
Note: B and D are the 2 twisted cables for the tamper loop.
E
Switching part (NC)
F
Tamper protection (internal reed)
G
EOL resistor
Description
The magnetic contact and the magnet must be mounted facing
each other in a window frame/door leaf and window
surround/door surround.
Caution:
Neither the contact nor the magnet can be installed
in ferromagnetic materials.
Special grade 3 magnetic contacts developed for installation in
ferromagnetic materials are available for this case.
The installation flange must only be mounted using screws
made of non-magnetic material.
When mounting is complete, the magnetic contact's electrical
switching function must be checked (e.g. using a continuity
tester or multimeter).
The application of mechanical force, e.g., when mounting the
device on the casing may damage the glass body of the reed
switch.
Only cyanacrylate adhesives (superglue) may be used to fix
the assembly parts. The processing instructions from the
respective manufacturer must be observed.
Caution:
Measure the supply lines electrically before
connecting them!
Distance Diagram
See Figure 3.
Minimum switch-on distance:
tolerance in x:
2 of 10
13 mm,
max. +/- 3 mm
Table 2
Proximity/switch-on distance
Distance/switch-off clearance
Technical Data
Flush-mounted magnetic contact DC128 for EOL zone types,
tamper protected.
Note:
Only front flush and surface-mounting possible.
Contact type
1 - pin NC contact
Switching distance
17 mm, +/- 4 mm
Switching voltage
max. 100 V DC
Switching current
max. 500 mA
Contact rating
max. 6 W or 6 VA
Contact resistance
max. 0.15 Ohm
Breakdown voltage
> 250 V
Permissible operating
max. 40 V
voltage
Connection cable
LIYY 4 x 0.14 mm Cu tin-plated;
Suitable for LSA IDC method of termination
External cable color
White
Internal conductor
Blue
Ø 8 x 32 mm
Contact dimensions
Ø 3.2 mm x 2 m (DC128)
Cable dimensions
Ø 3.2 mm x 6 m (DC128S60)
Ø 6 x 30 mm AlNiCo 5, axially polarized,
Magnet
in Ø 8 x 35 mm plastic sleeve
Housing material
S-B or A-B-S
Color
White
− 25 °C to + 70 °C
Temperature range
Protection category
VdS - environmental class III, IP 67
Scope of Delivery
Ø
1 magnetic contact
1 magnet Ø 6 x 30 mm AlNiCo 5 in plastic sleeve
Ø
8 x 35 mm
2 installation flange EF 8/10 for wood, plastic and non-
magnetic metals
4 fastening screws DIN 7982 - 2.9 x 13 - V 2 A
Regulatory information
European
UTC Fire & Security B.V., Kelvinstraat 7, 6003
Representative of
DH Weert,
Supplier
The Netherlands.
P/N 31494600.Y71 • REV 4 • ISS 18MAR19
Switch-on
Tolerance
distance [mm]
[mm]
17
+/- 4
22
+/- 4
8 x 32 mm