Outdoor
Electrical installation (for each display unit)
Caution: the display units must not be connected to mains before installation has been fully completed.
Cable kit option: control cables wall junction box
The transmission cable supplied is a telephone cable: type 2 pairs 6/10
Connect the control cable (Q) on the connector (T) of the scoreboard making sure that the colour code is followed (Please
note – RS485: Rx+ and Rx- must be connected on a twisted pair):
✓
Extract the electronic rack (R) from the scoreboard: unscrew the two nuts (B) with a 7 mm pipe spanner, then let the
rack (R) slide downwards.
✓
Put the connector (T) inside the scoreboard through the grommet (K).
✓
Plug the connector (T) on the electronic circuit board and fix the cable on the rack with a plastic collar (J).
✓
Put the rack (R) back inside the scoreboard and screw the two nuts (B).
✓
Fix the control cable into place making sure that it does not run alongside the 100-240V mains cables.
Connect the end wires into the junction box YBJ35 of the main scoreboard, making sure that the colour code is followed:
the cables of the different display units must be wired in parallel in the wall junction box.
Mains cables (P)
Connect the cable (P) to 100-240V Electrical power supply which should be located in a waterproof case. The electrical
power supply should be protected via a bipolar 4A circuit breaker (not supplied). Bipolar circuit breaker must be easy to
reach.
Control cable (Q): (1) = GND = blue wire / (2) = Rx+ = white wire / (3) = Rx- = grey wire / (4) = +24V = transparent wire
End of the installation
Turn on the power.
Try out the scoreboard operating functions (see operating functions).
ZI de Bel Air 44850 LE CELLIER FRANCE
IASCX40A-IM_F - Installation SCX40A
J
T
YBJ35
4
2
3
1
ths
.
T
1
2
3
R
K
B
B
A
Q
YBJ35
stramatel@stramatel.com Tél. +33 (0)2 40 25 46 90
4
P
100-240V
50/60Hz
Page 5