Herunterladen Diese Seite drucken

Balluff BTL7-C/E1 Serie Kurzanleitung Seite 4

Micropulse wegaufnehmer - bauform stab

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BTL7-C/E1-M _ _ _ _ -A/B/Y/Z(8)-SA42/327-KA_ _-ZA0C
Micropulse Transducer - Rod Style
EU Directive 2004/108/EG (EMC Directive) and EMC law
Noise immunity: EN 61000-6-1 / EN 61000-6-2
Emission: EN 61000-6-3 / EN 61000-6-4
Intended use
The BTL7 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories, use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.
Output signal with increasing
characteristic:
KA00,3 = 0.3 m cable length
~47
M12
Calibration device
3)
1
english
Error signal
100 %
0 %
Mounting surface
B: 30 – 1 mm
Z: 2"– 0.04"
BTL7...KA_ _
Thread size
B: M18x1.5
Z: 3/4"-16UNF
~53
~27
User's guide download
A complete standard user's guide can be downloaded
from the Internet at www.balluff.com/downloads-btl7
or requested via e-mail from service@balluff.de.
Dimensions and function
The transducer contains the waveguide. A magnet is
moved along the waveguide. This magnet defines the
position to be measured on the waveguide.
LED1
LED2
Operating state
Green
Off
Normal function (magnet is
within the measuring range)
Flashing
Not in measuring range (magnet is
red
outside the measuring range)
Red
Error (no magnet or magnet outside
the limits)
Zero point
End point
Nominal length
= Measuring range
Magnet
2)
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A8/B8/Y8/Z8-...
8 mm
Mounting surface
A: 30 – 1 mm
Y: 2" – 0.04"
Thread size
A: M18x1.5
Y: 3/4"-16UNF
File No.
E227256
Damping
zone
1)
G
LED 1
LED 2
G
Thread
M4x4/6 deep
Without thread
Unusable area
1)
Not included
2)
Not included with SA327
3)

Werbung