INSTALLATION

Choosing the place for installation (Fig.2)
The device must be placed vertically on a flat surface, in a dry and spacious location. The
room should be ventilated. At least 20 cm of clearance should be left around the device.
Water accumulates in the tank (8). An attached hose (9) can be used for water discharge.
The method of installation is described in "CONTINUOUS WATER DISCHARGE" section.

OPERATION OF THE DEVICE

Any changes in settings are signalled by a sound.
CONTROL PANEL (fig.3)
Display
-
when the power is on, it displays the humidity in the room,
-
if there is a problem with the device's operation, it shows error codes.
The color of the digits indicates the air humidity:
blue – humidity below 40%,
-
green – humidity between 40 and 60%,
-
red – humidity above 60%.
-
Indicator
- indicates that the water tank is full.
The indicator lights up red when the 2 liter capacity is reached.
The device will also indicate this with a sound, and then turn off.
Press any button to disable the sound alarm.
Then empty the water tank and put it back in the correct position.
Indicator
- automatic program
In this program, the dehumidifier maintains humidity in the range of 47% - 53% - the fan
operates at high speed.
If the ambient humidity rises above 53%, the device will start dehumidification to the
ambient humidity of less than 47%.
The compressor then stops and the fan will continue operating for approx. 30 seconds.
The device will restart when the humidity rises to 53%.
If the ambient humidity of ≤53% after connection, the device remains in standby mode
until the humidity rises to 53%.
Indicator
- continuous program
In this program, the dehumidifier operates continuously, regardless of air humidity - the fan
works at high speed.
Suitable for drying clothes or conditions requiring continuous dehumidification.