Herunterladen Inhalt Inhalt Diese Seite drucken

Nowy Styl eModel 2.0 Bedienungsanleitung Seite 17

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. 
Error messages on the display
Symbol on the
display
Description
Short circuit on DRIVE 1
Short circuit on DRIVE 2
The cable connecting
DRIVE 1 is disconnected
The cable connecting
DRIVE 2 is disconnected
No measurable
movement
System protection /
system stop. The control-
ler monitors operation
time and maximum
temperature. One of
the two values has been
exceeded.
Collision detected
Overload on DRIVE 1
Overload on DRIVE 2
Loss of DRIVE
synchronisation
Loss of controller
synchronisation
Anti- collision
sensor error
Conflicting operations on
two different controllers.
Solution
Unplug the power supply. Check cables
connecting the column to the control
module for damage or connect the appro-
priate DRIVE to the appropriate socket. If
needed, perform system initialisation / first
start-up following the user manual.
Check the connection of the cables con-
necting the column to the control module
and perform a restart/first start-up.
Unplug the power supply. Check cables
connecting the column to the control
module for damage or connect the appro-
priate DRIVE to the appropriate socket. If
needed, perform system initialisation / first
start-up following the user manual.
Wait for the control module to cool down
and the display to turn off. The controller
will allow movement for 20 s. After a break
of 18 minutes, the workstation can be
adjusted again constantly for maximum
2 minutes.
Remove the obstacle
Maximum load has been exceeded. Reduce
the load by removing extra items from the
desk top. Level the workstation with glides.
Perform system initialisation / first start-up
following the user manual.
Reduce the load by removing extra items
from the desk top- if applicable.
Level the workstation with glides. Perform
system initialisation / first start-up follow-
ing the user manual.
Check if the cables are properly connected
to the controller and the mains. Perform
system initialisation / first start-up follow-
ing the user manual.
Height adjustment is possible but without
the anti-collision system. Check the exter-
nal anti-collision sensor for connection to
the control module.
Stop the operation of all elements con-
nected to the control module
EN 17

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis