5.5 Parameter setting
Under OFF mode, hold
Parameter
Description
1
Priming time
2
Minimum RPM
6. PROTECTON & ERROR CODE
Item
Code
Description
1
E001
Abnormal input voltage
2
E002
Output over current
3
E101
Heat sink over heat
4
E102
Heat sink sensor error
5
E103
Master driver board error
6
E201
Circuit board error
7
E202
Master board EEPROM reading failure
8
E203
RTC time reading error
9
E204
Keyboard EEPROM reading failure
10
E205
Communication error
11
AL01
Auto speed reduction against high temperature
When error code appears, the device will stop working, to resume operation, unplug the device
and plug in again. AL01 is not an error indication, when it appears, product will switch
automatically to a lower speed for self-protection against high interior temperature, when the
temperature drops back to 65°C, product will resume preset speed.

7. EXEMPTION

Under no circumstances should the manufacturer be held liability for any consequences resulting
from inappropriate, incorrect installation, or mismatching of the product to pool pumps that are
not compatible.
Manufacturer reserves the right to change the specification of the product or its performance or
the contents of the User Guide without notice in case of technical upgrade.

8. WEEE LEGISLATION

When disposing the product, please hand it over to a designated collection point
for the recycling of waste electrical and electronic equipment.
The separate collection and recycling of waste equipment at the time of
disposal will help ensure that it is recycled in a manner that protects human
health and the environment. Contact your local authority for information on
where you can drop off your water for recycling.
AquaForte is a trademark of SIBO Fluidra Netherlands BV, Doornhoek 3950, 5465TC, VEGHEL,
www.aqua-forte.com,
info@aqua-forte.com
for 3 seconds to enter parameter setting.
Default setting
1 minutes
1200RPM
6
Setting range
1~10min, by 1 increment
1200~2000RPM, by 100RPM increment
Analysis
Not faulty
Not faulty
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier