TECHNICAL CHARACTERISTICS

BUS IN - Section
Nominal power voltage
Expansion operating voltage
Maximum current draw of expansion at 12 Vdc
(with relays energised, factory setting)
Maximum current draw of expansion at 12 Vdc (with
relays de-energised)
Nominal voltage on pin +V1:
Max. current that can be supplied from pin +V1:
Nominal voltage on pins +V2:
Max. overall current that can be supplied from pins +V2:
U1 output relay contact switching max. current and voltage:
Max. current that can be supplied from U2 and U3
electric outputs:
Max. total length of control panel-peripheral BUS line
(primary BUS)
Max. connection length between each sensor or
actuator and expansion
Max. length of connection between a fast (roller,
shock, ...) detector and the expansion:
Supplementary power section and BUS OUT
Nominal power voltage
Max. current absorption at 230 V (PS534–MW RS-50-15) 800 mA
PS534 power output nominal voltage (MW RS-50-15)
type A power supply
Max. current that can be supplied:
Max. current absorbed from power supply / repeater
electronics
Allocable battery
Battery charging nominal voltage
Max. current supply to charge battery
Max. time for recharging battery to 80%
Battery low threshold
Battery release threshold
Automatic battery test (controlled by control panel)
Max. current for external devices (keypads, sensors, sirens):
taken from + (BUS OUT), +, + terminals
Degree2–with ATS2 communication and 12 hrs autonomy
(total 1150 mA, of which 100 mA for electronics)
Nominal voltage on pin +SR
Max. current that can be supplied from pin +SR:
Nominal voltage on pin + (BUS OUT)
Max. current deliverable from + (BUS OUT) terminal
Nominal voltage on pins +
Max. total current deliverable from +V terminals
Max. total length of serial power supply-peripheral
BUS OUT line (secondary BUS)
Note 1): if battery is disconnected, at the ends of pin +BT –BT, no voltage is present.
Note 3): in case of lack of power supply, +SR provides no voltage.
Downloaded from
www.Manualslib.com
manuals search engine
13,8 Vdc (supplied by control panel BUS)
9 Vdc ÷ 15 Vdc
50 mA stand-by with balanced inputs
55 mA with NC inputs
40 mA with balanced inputs
45 mA with NC inputs
13,2 Vdc (supplied by control panel BUS)
500 mA (with overload protection)
13,2 Vdc (supplied by control panel BUS)
500 mA (with overload protection)
1 A – 24 Vdc with resistive load
10 mA
400 m
500 m
100 m
230 Vac +10% -15% 50/60 Hz
14,4 Vdc
3,4 A
100 mA
12 V – 18 Ah
note 1) 13,8 Vdc
500 mA
48 hours
11,5 V
10,5 V
every 24 hours (with mains)
1050 mA
note 3) 14,4 Vdc
200 mA (with overload protection)
13,8 Vdc ±1,5%
1100 mA (with overload protection)
13,8 Vdc ±1,5%
750 mA each (with overload protection)
400 m