TROUBLESHOOTING
No signal output.
Main power switch is on, but no LED's
are illuminated.
Check AC power source and cord.
Check fuses (pull fuse drawer under
power cord inlet)
>> Disconnect Mains before!
No signal output.
Main power switch is on and some
LED's are illuminated.
Check status of phantom power.
Check continuity of mic and electric
instrument cables.
Check continuity of output cables.
Output signal is distorted.
Outputs are connected for balanced
operation.
Make sure gain is adjusted so that
the OL indicator does not activate
during the audio program.
Make sure the high output capability
of this unit is not overloading the
device or monitoring system to which
it is connected set GAIN selector
to match capability of device or
monitoring system, then adjust gain
control according to indications on
the Level Indicator LED's.
Check continuity of output cable.
Make sure outputs are not con-
nected to a load impedance of less
than 600 ohms.
TRUE systems
Downloaded from
www.Manualslib.com
manuals search engine
0
Output signal is distorted.
Outputs are connected for unbalanced
operation.
Make sure the minus () output
signal pins are connected to the
screen (1) and not left unconnected.
See "Output Cable Connection"
section.
Check troubleshooting tips for bal-
anced operation (above).
Electric instrument
connected to a Direct Input does not
produce a signal or signal is distorted.
Check continuity of electric instru-
ment cables.
Check the batteries or AC power
source of any "foot pedal" effects
processors connected to the Direct
Input.
Make sure that the instrument
cables have standard tipsleeve 1/"
phone plugs. DO NOT use TRS
plugs.