ALC2-1.book Seite 15 Donnerstag, 25. Juni 2015 10:28 10
Technical specifications
Visible laser diode
Laser class
Work area
– Horizontal/vertical beam
Precision ...
– Horizontal/vertical beam
Self-levelling range
Power supply
Operating duration
Temperature range
– for operation
– for storage
Weight (with batteries)
1) The measurement range may be less under
unfavourable conditions (bright sunlight,
reflective surfaces).
Downloaded from
www.Manualslib.com
Cross-line laser ALC 2/1
1)
± 0.3 mm/m
2)
–5 °C ... 50 °C
–20 °C ... 70 °C
manuals search engine
2) The operating duration was determined with all
activated laser beams. The operating duration can
be extended if beams which are not required are
switched off by selecting a different operating
mode.
635 nm
Instructions for use
2
WARNING!
20 m
– Do not point the laser beam at people or
animals.
– Do not look into the laser beam.
– Do not put any optical instruments in the path
± 4°
of the beam.
This measuring instrument generates laser
3 x LR6/AA
radiation which may cause blindness.
12 h
CAUTION!
– Do not use the measuring instrument in
a damp, dusty or sandy environment.
Device components may be damaged.
– After using the device, immediately switch it
421 g
off with the On/Off switch in order to block self-
levelling.
– If the device is brought from a very cold to
a warmer environment or vice versa, you
should allow the device to acclimatise before
using it.
FLEX ALC 2/1–Basic