Idrogas Celsior-1 Gebrauchsanleitung Und Pflege Seite 7

Elektrischer warmwasser-speicher
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
Made of steel protected form corrosion by a special glass-ceramics
coating
Made of stainless steel
The vertical water heaters may be out tted with a built in heat
exchange unit (boiler tube). The boiler tube's entrance and exit are
located at the sides and represent pipes with thread G ¾ '' .
The ange is out tted with: electric heater and thermostat.
2.
The water heaters with glass-ceramics coating are out tted with a
magnesium protector.
The electric heater is used for heating the water in the tank and is
managed by the thermostat, which automatically maintains the set
temperature.
The thermostat has a built in overheating safety device, which switches
of power to the heater when the water temperature reaches excessive
values.
The safety-return valve prevents the appliance's complete
3.
emptying in the event the cold water supply is interrupted. The
valve protects the appliance from pressure increases higher than the
allowed value during heating (! pressure increases upon an increase
of temperature), via release of excess pressure during the drainage
opening.
The safety-return valve cannot protect the appliance in the
event of water mains pressure in excess of the acceptable
pressure stated for the appliance.
V. MOUNTING AND SWITCHING ON
1. Mounting
We recommend the mounting of the device at close proximity to
locations where hot water is used, in order to reduce heat losses during
transportation. In the event the device is mounted in a bathroom, the
selected location must exclude the possibility of water spray contact
from the showerhead or portable showerhead attachment.
The appliance is a xed to a wall via the mounting brackets attached to
the unit's body (if the brackets are not attached to the unit's body, they
must be a xed in place via the provided bolts). Two hooks are used
for suspending the appliance (min. Ø 10 mm) set rmly in the wall (not
included in the mounting set). The mounting bracket's construction
designed for water heaters intended for vertical mounting is universal
and allows a distance between the hooks of 220 to 310 mm ( g. 1a).
For water heaters intended for horizontal mounting GCH; GCVHL, the
distances between the hooks vary for the di erent models and are
speci ed in the table 2 to Fig. 1b, 1c. For water heaters intended for
oor installation - table 2 to Fig. 1d.
In order to prevent injury to user and third persons in the
event of faults in the system for providing hot water, the
appliance must be mounted in premises out tted with oor hydro
insulation and plumbing drainage. Don't place objects, which are
not waterproof under the appliance under any circumstances. In
the event of mounting the appliance in premises not out tted
with oor hydro insulation, a protective tub with a plumbing
drainage must be placed under the appliance.
NOTICE: THE SET DOES NOT INCLUDE A PROTECTIVE TUB AND
THE USER MUST SELECT THE SAME.
2. Water heater connection to the pipe network.
Fig. 4: a) - for vertical; b) - for horizontal installation; c) - for oor
installation
Where: 1 - Inlet pipe; 2 - Safety valve; 3 - reducing valve (for water main
pressure > 0,6 MPa); 4 - Stop valve; 5 - Funnel connected to the sewer
network; 6 – Hose; 7 - Drain water tap.
Upon connecting the water heater to the water mains you must consider
the indicative color markings /rings/ a xed to the pipes: blue for cold /
incoming/ water, red for hot /outgoing/ water.
English
The mounting of the safety return-valve supplied with the water heater
is obligatory. The safety return-valve must be mounted on the cold water
supply pipe, in observance of the direction arrow stamped on its body,
indicating the incoming water's direction. Additional stopcocks must not
be mounted between the safety return-valve and the water heater.
Exception: If the local regulations (norms) require the usage of another
protection valve or mechanism (in accordance with EN 1487 or EN
1489), then it must be bought additionally. For mechanisms operating in
accordance with EN 1487 the announced operational pressure must be
no more than 0.7 MPa. For other protection valves, the pressure at which
they are calibrated must be 0.1 MPa lower than the one marked on the
appliance's sign. In these cases the safety valve which the appliance is
supplied with should not be used.
The presence of other /old/ safety return-valves may lead to a
breakdown of your appliance and they must be removed.
Other type of stopping armature is not allowed between the
protection return valve (the protective device) and the appliance.
The attaching of the safety return-valve to threads longer than
10 mm is not allowed, otherwise this may damage the valve
and poses danger for your appliance.
With boilers for vertical assembly, the safety valve has to be
connected to the ingoing pipe with the safety plastic panel of
the appliance being taken o . After it has been assembled it should be
in position as shown on Fig. 2.
The safety valve and the pipe between the valve and the water
heater must be protected from freezing. During hose draining
- its free end must be always open to the atmosphere (not to be
immersed). Make sure that the hose is also protected from freezing.
Opening the cold-water stopcock of the water supply piping network
and opening the hot-water stopcock of the water-mixing faucet
carries out the lling of the water heater with water. After the lling
is complete, a constant stream of water must begin to ow from the
water-mixing faucet. Now you can close the hot water stopcock.
In the event you must empty the water heater, rst you must cut o
its power supply. The in ow of water from the water mains must rst
be terminated and the hot water tap of the mixing-faucet must be
opened. The water tap 7 ( g 4a and 4 b) must be opened to drain the
water from water tank. If there is no such tap build in the pipe line, than
the water can be drain as follow:
Models equipped with safety valve with lever - You can drain the
water from the water heater by lifting the safety return-valve's lever.
Water will drain from the safety return-valve's drainage opening
Models equipped with safety valve without lever - water can be
drain directly from inlet pipe of water tank after when you disconnect
it from water main
In the event of removing the ange, the discharge of several liters of
water, which remain in the water tank, is normal.
Measures must be undertaken to prevent damage from
discharging water during draining.
In case that the pressure in the water mains is over the value
pointed out in the above paragraph I, then it is necessary to
assemble a pressure reduce valve, otherwise the water heater
would not function properly. The Manufacturer does not assume
any liability for problems arising out of the appliance's improper
use.
Instructions for use and maintenance
EN
7