D. ERROR MESSAGES
In case of faults, the battery charger displays the following messages:
SIGNAL
CAUSE
Polarity inversion: the
output conductors
clamps are not properly
connected to the
REVERSE
battery.
Battery with too high
voltage (attempt
to charge a 24 Volt
battery).
Battery with excessive
capacity.
The battery cannot
maintain a good charge
level.
FAULT
Very low charged
battery.
Disconnected cables or
short circuited.
Battery completely
short circuited.
REMEDY
Place correctly the clamps and
resume the battery charge (see
paragraph "C").
Check the battery voltage. GET
Battery Charger can only be used
with batteries with a 12 Volt
maximum voltage.
Check the battery capacity. GET
Battery Charger can only be used
to charge batteries with a capacity
between 2 and 40 Ah.
The battery might be defective.
Check the status with a specialised
technician.
Press again the button to restart
the charge and try to recover the
battery.
Place correctly the clamps and
resume the battery charge (see
paragraph "C").
The battery might be defective.
Check the status with a specialised
technician.
10