10. Application of data carriers

Storage media are referred to as ID data carriers on which authorization data are saved.
ID data carriers are available in different geometrical shapes.
Only LEGIC cards and keychains can be used as data carriers.
The LEGIC prime data carrier can be used parallel to LEGIC advant data carriers.
Correct application of data carriers:
The data carrier should be held approximately in the middle of this range.
The reading distance is at least 3 cm (depending on data carrier).
Reading range
Influence on the read process by other data carriers:
In order to prevent several data carriers affecting the read process, ensure that the
desired data carrier is held separately in the reading range.
When using several transponders of the same frequency range (13.56 MHz), reading
errors can occur with insufficient distance between the transponders.
There is no safety risk, only the reading will be prevented if there are several
transponders within the reading area.

11. Application and operation with AC panels

The LEDs and the buzzer are controlled over a bus sys-
LEDs
tem.
green yellow red
The definition for each is specified in the main software
and not at the reader.
At readers with
lights permanently and can not be switched off.
At readers with
switched dark via software.
Numeric keypad for PIN entry
(PIN = Personal identification number)
Macro control
LED meaning
Colour Basic
After reading
condition a card or after
a keystroke
yellow
on
Operation / ready to read
yellow
off
Device is idle
PIN-Code or door code entry is active
(only possible with readers with RS-485 interface)
green
on
Permanently released
red
on
Permanently blocked
green
on
Door release
red
on
ID card not authorized
red
blinking
Read error
Additionally, the LED functions of the macro control of IQ MultiAccess are valid (see
separate manual "Supplementary functions of IQ MultiAccess", P32205-46-0G0-xx).
Access control function
An authorization is granted if a authorized data carrier is held in the reading range. The
data carrier must be authorized in the system.
Readers with keypad provide the following options for the authorization:
- Data carrier only, PIN and data carrier, PIN or data carrier
The sequence of PIN and data carrier is arbitrary.
Reader Data
carrier
Side view
Clock/Data interface
the yellow LED
RS-485 interface
the yellow LED can be
Meaning

12. Application with IDS

12.1 Functions
Arming/Disarming and/or AC function.
-
Only with data carrier (reader without keypad is operated with toggle)
-
With PIN and data carrier
-
With PIN or data carrier
12.2 Installation
Important note:
The
power supply
should be established via a
due to the high reader power consumption (e.g. U_ext. from central control
unit or separate power supply unit).
-
The installation in accordance with Chapter 8, must be completed.
-
Connect the reader to the IK3 EU/DCM.
Please note the IK3 EU/DCM Mounting and Connection Instructions.
12.3 Create reader
Create reader as IK3 operating unit with serial number 00000-00000.
Several readers with the serial number 00000-00000 can be created with IDCU firm-
ware from version V05.09 and WINFEM Advanced V01.xx onward.
Please note that no keypad code may be input in the case of readers without a key-
pad, and "data carrier only" should be set for authorisation.
12.4 Authorisation of data carriers
The code given on the data carrier cannot be used, as codes different to those used
in the access control application are utilised in intrusion detection technology. Data
carriers must therefore be taught in.
IK3 EU BUS-2 and Door controller module:
Data carriers are taught in with the aid of one-man revision
-
F:402 "Check switching device"
and subsequent use of a learn master key
-
F:308 "Learning monitor".
Learn master keys are created if necessary in these functions. The code valid
for intrusion detection technology is displayed by a taught-in data carrier and
can then be input as a learn master key code.
IK3 EU conventional:
See Manual WINFEM Advanced (P03174-20-00x.xx).
To
learn data carriers in the learning mode
on the firmware version of IK3 EU BUS-2 / DCM)

13. IDS Operating Instruction 1

for IK3 EU BUS-2, DCM BUS-2 up to V10.xx,
IK3 EU conventional
For IK3 EU BUS-2 / DCM BUS-2
IDS Operating Instruction 2, Chapter 14.
13.1 Operating and indication elements
!
LED indication and keypad:
LEDs
green: ready
yellow: disarmed
green yellow red
red:
Alarm
The state of the indicator is as follows:
Disarming Arming
Numeric keypad for PIN entry
(PIN = Personal identification number)
!
Buzzer signal:
There is an acoustic acknowledgement by a long buzzer signal.
There is no differentiation between reading acknowledgment,
positive or negative acknowledgment.
separate protected source
see Chapter 13.5 or 14.5 (depending
from V11.xx
see
When idle, all indicators remain dark. When
a function is being performed, the indicator
is actuated for approx. 5 seconds according
to the function. For details see following
Chapters.
blinking
on
off
1 sec.