Configuration possibilities

Clock/Data
Host-
System
max. cable length 10 m
RS-485-Bus (2-wire)
Host-
System
max. cable length 1200 m
6.

Terminal allocation

Terminal block 9 poles, pluggable
The wiring of the back module must be done in voltageless condition,
which means the operating voltage must may be switched on after
finishing the complete installation only.
Concerns ACS-1, ACT, ACS-2, ACS-2 plus and ACS-8:
If the
Clock/Data interface
is used, connect a 1k2 resistor from U_b (pin 8) to LED
yellow (pin 3).
7.

DIP switch setting for RS-485 interface

(no setting required for Clock/Data interface)
DIP
F
unction
switch
S1 - S5 RS-485 Address
S6, S7
internal used,
don't change
OFF
RS-485 without EOL resistor
S8
ON
RS-485 with EOL resistor
Details to the end-of-line resistor see Installation Instuction of the Controller.
Power supply
LED control
Clock/Data
Power supply
RS-485 Bus
16x on ACS-8,
4x on IK3 EU,
2x on DCM
Pin no. Clock/Data
RS-485
1k2
1
Clock
internal used
(see
2
Data
internal used
below)
3
LED yellow
internal used
4
LED green
internal used
5
LED red
internal used
6
internal used A (D)
7
internal used B (D*)
8
+U_b
+U_b
9
0 V
0V
The reader automatically identifies the inter-
face used during the "Start up" procedure.
Terminal specification
:
Lift system
Connection diameter 0.4 – 1.4 mm
Stripped length of wire 5 mm
on
off
1 2 3 4 5 6 7 8
1 2 4 8 16
Valence
End-of-line resistor
Address RS-485
DIP switch
1
2
3
4
5
1
0
0
0
0
0
1
0
0
0
1
1
0
0
0
0
0
1
0
0
1
0
1
0
0
0
1
1
0
0
1
1
1
0
0
0
0
0
1
0
1
0
0
1
0
.
.
.
1
1
1
1
1
0
0
0
0
0
Mounting and Operating Instructions LEGIC advant reader Feller
8.

Mounting

8.1
Preparation
Carefully separate modules.
Front module
Front module and Back module
assembled
8.2
Install Back module
2
1
1
Plug wired terminal block
2
Screw module to the Feller f.m. socket and align horizontally.
3
Insert the 4 clamping sleeves.
4
If still required, set DIP switches as per chapter 7.
8.3
Install Front module
Position the Feller EDIZIO bezel on the wall and
hold in place.
Position the pin row and the clamping pins of the
front module against the back module and press
it gently.
9.

Demounting

Switch off power supply.
Address
Slide a screwdriver or a similar large-scale thin object
1
gently between bezel and the wall.
2
Slowly loosen the clamping by equably sided
3
levering.
4
5
Once the frame has solved of the wall, grasp the
6
frame with your fingers and pull it forward until the pin
7
row and the clamping pins are completely separate
8
from the back module.
9
31
32
Back module
Back module
Modules separated
2
3
4
3
2
de-energized
in the back module.
Press the front module as far
toward the back module until the
front module completely immersed
in the EDIZIO bezel and this rests
on the wall.
Front module
2
3
3
2