14.5 Learning mode for data carriers
In learning mode it is simple to authorize new data carriers or delete existing ones.
Newly "learned" data carriers automatically receive
version V09 (MB24/48/100) and version V03 (MB256 plus), the PINs / authorizations /
time zones must be assigned afterwards via the programming functions .
To start the learning mode, you need a
exclusively for this purpose in the system. However, the learning key has no
authorizations.
As long as learning mode is activated, you can enter or delete as many data carriers as
you want one after another.
Learning mode is possible only in the disarmed state.
The "Ready" LED (green) and the "Disarmed" LED (yellow)
LED indication:
serve as a
mode.
green yellow red
The red LED lights up in case of alarm.
Buzzer signals:
- Positive acknowledgement:
- Learning mode activated
- Data carrier authorized
- Data carrier erased
- Negative acknowledgement:
Invalid action.
An invalid action is given if a programmed data
carrier is to be learned or an unprogrammed data
carrier is to be erased.
!
Reader with keypad
Start learning mode
Hold the learning key in the reading field until buzzer signal
L
LEDs green and yellow light up
E
Press the
"E"
button
LEDs green and yellow start flashing,
the learning mode is activated
Learn data carrier
Hold the new data carrier in the reading field until buzzer signal
ID
LED green is on, LED yellow flashes
E
Press the
"E"
button, short buzzer signal
LEDs green and yellow are flashing
Delete data carrier
Hold the old data carrier in the reading field until buzzer signal
ID
LED green is on, LED yellow flashes
C
Press the
"C"
button, 2 short buzzer signals
LEDs green and yellow flashing
Exit learning mode
Hold the learning key in the reading field until buzzer
C
C
L
L
signal, then press the
or
only press the "C" button
C
C
or
Exits automatically approx. 60 seconds after the last operation
All LEDs off
Honeywell Security and Fire Solutions
Novar GmbH
Johannes-Mauthe-Straße 14
D-72458 Albstadt
www.honeywell.com/security/de
general authorization
"learning key"
. This is a data carrier set up
visual acknowledgement signal
in learning
2 sec.
Positive
1 sec.
Negative
red lights up in case of alarm
green yellow red
,
short buzzer signal
"C"
button
P30731-45-002-02
2017-06-28
© 2017 Novar GmbH
Mounting and Operating Instructions LEGIC advant reader Feller
!
Reader without keypad
Start learning mode
, as of
Hold the learning key in the reading field until buzzer signal
L
LEDs green and yellow light up
LEDs green and yellow start flashing,
the learning mode is activated
Learn data carrier
Hold the new data carrier in the reading field until buzzer signal
ID
LED green is on, LED yellow flashes
short buzzer signal
LEDs green and yellow flashing
Exit learning mode
Hold the learn master key in the reading range until buzzer signal
L
or
Exits automatically approx. 60 seconds after the last operation
All LEDs off

15. Technical Data

Operating voltage
Operating voltage range
Power consumption
Interfaces:
-
RS-485
-
Clock/Data
Signalling elements
Reading distance
Frequency range
Transmission power
Protection category as per EN 60529
Operating temperature range
Storage temperature range
Dimensions:
- Reader (W x H x D)
- Bezel (W x H x D)
Supported data carriers:
LEGIC MIM 22 / MIM 256 / MIM 1024
LEGIC ATC512-MP110 (ISO 14443A)
LEGIC ATC2048-MP110 (ISO 14443A)
LEGIC ATC4096-MP310 (ISO 14443A)
LEGIC ATC4096-MP311 (ISO 14443A)
Hereby, the Novar GmbH declares that the radio equipment LEGIC
advant reader Feller without keypad, Item no. 027665.10.FE, with keypad
Item no. 027665.20.FE and mifare DESFire EV1 reader "Accentic"
no. 026435.10, 026436.10
The full text of the EU declaration can be downloaded from our homepage
https://www.security.honeywell.de/ in the service/download area.
red lights up in case of alarm
green yellow red
12 V DC
8 to 30 V DC
max. 90 mA at 30 V DC
max. 35 mA at 12 V DC (online operation)
Module bus, (D, D*)
not
galvanically separated,
addressing via DIP switches,
switchable terminating resistor (DIP switch)
TTL level, 4 bit code according to DIN 9785,
resting level high
3 LEDs green, yellow, red
1 Piezo buzzer
³
3 cm (depends on data carrier)
13,56 MHz
4.5 dBµA/m, distance 10 m (max.)
depending on Feller housing
-25 °C to +60 °C
-30 °C to +70 °C
70 x 70 x 17 mm
88 x 88 x 7.3 mm
LEGIC AFS4096-JP10/JP11 (ISO 14443A)
LEGIC ATC128-MV210 (ISO 15693)
LEGIC ATC256-MV210 (ISO 15693)
LEGIC ATC1024-MV110 (ISO 15693)
is in compliance with Directive 2014/53/EU.