User Guide Riversoft
Design specifications/ratings
Softener cabinet ...............................................ABS
Tank body..........................................................Dowex
Valve body .........................................................Glass-filled Noryl
Rubber components .........................................Compounded for cold water - NSF listed material
Valve material certification ..............................WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS
Volume of resin.................................................4 L ........................8 L ........................15 L ......................30 L
Approximative shipping weight ........................9.5 kg....................16.5 kg..................27 kg ....................30 kg
Salt storage.......................................................6 kg.......................25 kg.....................50 kg ....................50 kg
Operating pressure...........................................1.4 - 8.6 bar
Hydrostatic test pressure.................................20 bar
Water temperature ...........................................4 - 38°C
Ambient temperature .......................................2 - 50°C
3.1.2. Performance flow rate characteristics
NOTE
Flow rates are indicative data. Maximum flow rate to produce in order to respect the required service
velocity for an optimal ion exchange upon resin manufacturers recommendation, regardless of the
inlet pressure.
Softener
Nominal (residual hardness 0 mg/L as CaCO
Nominal (residual hardness 50-100 mg/L as CaCO
Peak (residual hardness mg/L as CaCO
Softening
Number of people .............................................POU* ....................1-2 ........................3-4........................5-8
* assuming a 200L per day water consumption at POU (Point Of Use).
Capacity & salt consumption for the different salt dosage setting
Softener
Corresponding salt dosage (g/L of resin)
Salt amount per regen (kg)
Capacity (kg as CaCO
) to program (override preprogrammed
3
capacity)
3

Capacity in m

(for 300ppm inlet hardness and 100ppm residual
hardness)

Estimated salt consumption per year (kg) for 200 L daily water

consumption per person and 300 mg/L as CaCO

residual 100 mg/L as CaCO

8 / 132
®
3
) [m
/h]
3
) [m
3
3
) [m
/h]
3

inlet hardness,

3
3
HCRS-s resin
®
- NSF listed material
4
0.2
3
0.3
/h]
0.4

Riversoft 4

80
0.3
0.16
0.79
28.8
Riversoft
8
15
0.5
0.9
0.6
1.1
0.8
1.5
Riversoft 8
120
200
80
0.5
0.8
0.6
0.2
0.24
0.32
0.98
1.22
1.60
14.2 -
34.9
46.6
28.4
Ref. MKT-UG-045 / A - 13.03.2020
30
1.8
2.2
3.0
120
200
0.9
1.6
0.4
0.5
1.98
2.48
17.2 -
23-46
34.5