Fresh-water connection
Connect the inlet hose to a water tap using
the enclosed parts and in accordance with
the installation instructions.
Water pressure:
Minimum 0,5 bar – maximum 10 bar.
If the water pressure is higher, install a
pressure reducing valve.
Flow rate:
Minimum of 10 litres per minute.
Water temperature:
We recommend that you use cold water.
If you do use hot water, the temperature
should not exceed 60 °C.
Electrical connection
This appliance should only be connected
to a 230/240 V AC source via a properly
installed earthed socket. See nameplate
for size of required fuse.
32
The socket must be installed close to the
dishwasher.
If you need to extend the mains
connecting lead, do not cut off the plug.
Replace the whole cable, which can be
disconnected at the junction box on the
rear of the appliance.
If the domestic wiring includes a residual-
current-operated (FI) circuit-breaker, make
sure that it bears the
this type conforms to the latest regulations
42
mark, as only
Disconnecting the dishwasher
Here too, it is important that tasks are
carried out in the correct sequence:
always unplug the appliance from the
mains electricity first of all.
Pull plug out of wall socket.
Turn off water supply.
Disconnect drain and water input hoses.
Remove screws in underside of work
surface. Detach base board, if fitted.
Pull out appliance and carefully withdraw
hoses at same time.
Transporting the dishwasher
Drain water from the dishwasher. Secure
all loose parts. The appliance should only
be transported in an upright position.
If the appliance is not kept upright
during transport, any water left inside
may seep into the control module and
cause subsequent errors with
programme functions.
Protection from freezing
temperatures
If the appliance is installed in a location
where there is a risk of freezing
temperatures (e.g. in a holiday home), all
water must be completely drained out of
the interior.
Turn OFF the tap, disconnect the supply
hose and allow to drain.