Herunterladen Inhalt Inhalt Diese Seite drucken

Protective Measures - Swep FWS100 Bedienungsanleitung

Frischwasserstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
6.2
INSPECTION OF PIPEWORK ON
PREMISES
The instructions require the fresh water station
to be connected to the hot water, hot water
circulation and cold water pipework on the
premises.
Check
that
components in accordance with the
technical documentation
delivered.
Check that the planned location of the
fresh water station is suitable. Plan any
openings
and
pipework.
6.3

PROTECTIVE MEASURES

Take protective measures if the work is
carried out during weather that may
cause damage.
Protect your own work, including the
fresh water station if it could be
accidentally damaged during the contract
period.
Fit protective covers/plug exposed pipe
ends on the fresh water station's primary
and secondary sides to protect against
dirt, damage, or foreign objects.
Ensure that materials or auxiliary devices
in place do not obstruct access to or
conceal
shut-off
equipment, fire hydrants, fire cabinets,
gullies, distribution boxes, measurement
points, etc.
Keep the work area tidy and clean during
installation.
6.4
FLUSHING, PIPE CLEANING
Clean the pipework connected to the
premises before connecting the fresh
water station.
Components such as automatic air vent
valves and solenoid valves that may be
damaged during flushing must not be
connected or activated during flushing.
Flush with mains tap water. Allow dirty
water to discharge into floor drains. Flush
for at least 30 minutes or until the water
discharged is clean.
6.5
CONNECTION OF FRESH WATER
STATION
6.5.1
Pipework
NOTE: All installation of pipework must be
carried out in the required manner by authorized
personnel (see Section 5 Safety).
all
secondary-side
have been
break-throughs
for
and
inspection
Connect
the
station's
connections as follows:
inlet
and
outlet
Incoming cold water
Outgoing hot water
From tank
To tank, high-
temperature
To tank, low-
temperature

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fws200

Inhaltsverzeichnis