Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning; Remedy Of Faults - Oase LunAqua Classic LED Set 1 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für LunAqua Classic LED Set 1:
Inhaltsverzeichnis

Werbung

- GB -
Start-up
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Switching on: Insert the power plug of the transformer into the socket.
− Check the function of the spotlights.
Switching off: Disconnect the transformer power plug.

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
− Ensure that no moisture can enter the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
Replacing the bulb (D)
− Unscrew the threaded ring (6).
− Remove the glass pane (7) and O ring (8) and check for damage. Replace if necessary.
− Remove the defective bulb (9) from the housing (1).
− Insert a new bulb (do not touch with your hands, use a cloth or similar).
Only use original bulbs from OASE. Light bulb rating: max. 1 W.
− Reassemble the unit in the reverse order. Ensure that the O ring (8) is correctly positioned.
− Reconnect to the power supply and check the function.

Remedy of faults

Malfunction
Lamp does not light up
Luminosity decreases
Water inside the spotlight housing
S
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
8
Cause
Power supply interrupted
Bulb defective
Lamp glass soiled
The brightness of the bulb reduces as the
operating time increases
Seal defective
Remedy
Check power supply
Replace bulb
Clean
Replace bulb
Check sealing rings and replace, if necessary

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lunaqua classic led set 3

Inhaltsverzeichnis