Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens 7XV5662-0AD00/DD Handbuch Seite 73

Kommunikationsumsetzer 2m
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7XV5662-0AD00/DD, 7XV5662-0AD01/DD
Continuous Shock IEC
60255-21-2, Class 1
IEC 60068-2-29
Climatic Stress Tests
Temperatures
recommended temperature range for
operation
permitted temperature range for operation
recommended temperature range during
storage
permitted temperature range during storage -40 °C to +85 °C (-40 °F to +185 °F)
permitted temperature range during trans-
port
Humidity
Admissible humidity conditions
All devices shall be installed so that they are not exposed to direct sunlight, nor subject to
strong fluctuations in temperature that may cause condensation to occur. Storage and
transport with original packing!
Constructive Design
Case
Measurements
Weight
Degree of protection
Mounting housing
Interface side
Screw Torque
Terminal screw
Grounding screw
C53000-B1174-C205-2
Downloaded from
www.Manualslib.com
Semi-sinusoidal
10 g acceleration, duration 16 ms, each 1000 0160 shocks
in both directions of the 3 axes
manuals search engine
IEC 60068-2
-10 °C to +55 °C (+14°F to +131 °F)
-25 °C to +55 °C (-13 °F to +131 °F)
+10 °C to +35 °C (+50 °F to +95 °F)
-40 °C to +85 °C (-40 °F to +185 °F)
= 75 % relative humidity, on 56 days of the
year up to 93 % relative humidity, conden-
sation must be avoided!
188 mm × 120 mm × 55 mm (W × D× H)
0.8 kg (1.8 lb)
According to EN 60529
IP 41
IP 2x
0.4 Nm to 0.5 Nm
1.2 Nm
English
73

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

7xv5662-0ad01/dd