TYPICAL WIRING DIAGRAM
L
N
GND
110/230Vac IN
1 - SETTING RELAY FUNCTION (IMPULSIVE, ON/OFF, TIMER)
Before starting select the output L1 or L2, using the switch (see picture at page 5).
The following configuration will be applied only to the selected output.
Warning: the receiver automatically saves the settings 5 seconds after the button release.
1.1 - IMPULSIVE FUNCTION
Press once SET button and hold it down until the IMP led turns ON. Release
the button and wait until the led turns off, to confirm the memorization of
the data.

1.2 - ON/OFF FUNCTION

Press twice SET button and hold it down the second time, until the ON-OFF
led turns ON. Release the button and wait until the led turns off, to confirm
the memorization of the data.

1.3 - TIMER FUNCTION

1- Setting the seconds (1 to 59)
(a) Press 3 times SET button and hold it down the last time, until the SEC led
turns ON. (b) Adjust the seconds increasing with MEM button or decreasing
with DEL button. Each press corresponds to a unit increased or decreased.
Wait for exit the procedure saving the data or proceed with the next setting.
2- Setting the minutes (1 to 59)
(c) Press the SET button another time (within five seconds) and hold it down
until the MIN led turns ON. (d) Adjust the minutes increasing with MEM button
or decreasing with DEL button. Each press corresponds to a unit increased
or decreased. Wait for exit the procedure saving the data or proceed with
the next setting.
3- Setting the hours (1 to 8)
(e) Press the SET button another time (within five seconds) and hold it down
until the HOU led turns ON. (f) Adjust the hours increasing with MEM button
or decreasing with DEL button. Each press corresponds to a unit increased
or decreased. Wait for exit the procedure saving the data.
Note: once reached the maximum or minimum limit, the led will turn off and the value will no longer be increased or decreased.
L1
L2
6
N
L2
L
110/230Vac
E
3000W max. (@ 230Vac)
1500W max. (@ 110Vac)
N
L1
L
110/230Vac
3000W max. (@ 230Vac)
E
1500W max. (@ 110Vac)
(a)
(c)
(e)
(b)
(d)
(f)