7. Dismantling and Re-Installation
8.
9.
10.
Leave the hydraulic oil in the
loosened shrink disc and tightly
close the connections "HP" and
"T" once more with screw plugs.
Remove the shaft or pull off the
hub with shrink disc from the shaft
NOTE
Where necessary, remove any
rust which may have formed
on the shaft in front of the
shrink disc.
Pull the shrink disc from the hub.
[ EN ]