LED-SIGNALS

The RED or GREEN
LED is ON sporadicly
or permanently.
The sensor does not
react, but a calibration
can be launched.
The ORANGE LED is
on permanently.
The ORANGE LED
flashes quickly.
The ORANGE LED
flashes 1 x
1
every 3 seconds.
The ORANGE LED
flashes 2 x
2
every 3 seconds.
The ORANGE LED
flashes 3 x
3
every 3 seconds.
The ORANGE LED
flashes 4 x
4
every 3 seconds.
The ORANGE LED
flashes 5 x
5
every 3 seconds.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance
with applicable national and international regulations and standards on door safety.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualified personnel may install and setup the sensor.
- The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.com - www.came.com
CAME hereby declares that MR8534/MR8570/MR8590 is in compliance with European
directives 2014/30/EU (EMC), 2006/42/EC (Machinery) and 2011/65/EU (RoHS).
Original upon request.
This product should be disposed of separately from unsorted municipal waste.
BUY-TO-SELL PRODUCT
Bad calibration
Bad adjustment of the
uncovered zone.
The sensor is disturbed by
lamps or another sensor.
The monitoring is activated,
but the test input is not
powered.
The sensor encounters a
memory problem.
DIP-switch setting
awaiting confirmation.
The sensor signals an
internal fault.
Power supply is out of limit.
Communication error
between modules.
The sensor receives
not enough IR-energy.
Calibration error
1
Launch a calibration.
1
Check if the DIP-switch 4 is in correct position.
2
Launch a calibration.
1
Select a different frequency for each module (DIP 2).
Launch a calibration.
2
Chech wiring.
1
- Door control with test:
Connect RED and BLUE wires to test output.
- Door control without test:
Connect BLUE to 0 V and RED to +12 V - 30 V DC.
1
Send the sensor back for a technical check-up.
Corfirm the DIP-switch setting:
1
long push on the push button.
1
Cut and restore power supply.
2
If orange LED flashes again, replace sensor.
1
Check power supply (tension, capacity).
2
Reduce the cable length or change cable.
Check wiring between modules.
1
Launch a module count: long push on push button
2
of MASTER.
Launch a new calibration and step out of
1
the detection field.
2
Change angle of spots.
3
Switch off background (DIP 3: OFF).
1
Check mounting height.
2
Change position of calibration screw.
3
Launch a new calibration.
4
Switch off background (DIP3: OFF)