Herunterladen Inhalt Inhalt Diese Seite drucken

Supplementary Instructions For Explosion-Proof Models - Panasonic FZ-X1AFAB Serie Bedienungsanleitung

Ergänzende anweisungen für explosionsgeschützte ausführungen
Vorschau ausblenden Andere Handbücher für FZ-X1AFAB Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
Supplementary instructions for
explosion-proof models
Thank you for purchasing a Panasonic product.
Please read this document and the unit's Operating Instructions
carefully before using the product and keep this document in a safe
place for future reference.
Please confirm the warranty period of this product in the Operating
Instructions.
ATEX Information
ATEX Certificate of Conformity no.: CML 15 ATEX 4069X
Ex-Marking:
Ambient temperature:
IP of degree:
Confirms to
• This product is intended for use in non-hazardous or hazardous
location classified as EPL Gc, Zone 2.
• This product is specified Temperature class T4.
• Models FZ-X1AFAB / FZ-X1CFAB / FZ-E1BFCB / FZ-E1DFCB
have a high frequency power greater than 2 W but less than 3.5 W,
and are suitable only for Gas Groups IIA and IIB.
Note
• For detailed information about "Temperature class" or "Gas
Groups", refer to EN 60079-0.
2
II 3G Ex nA nC IIB T4 Gc
-20 °C to 40 °C
IP54