UK
At start up switch the device on again by pressing any key. If the free chloride level is lower than
1 particle by million, run a shock chlorination and follow the start-up procedure (check the water
parameters, the rate of salt, state of the cell, of the chlorine production percentage).
Damages linked to non-compliance with these instructions will cancel the warranty.
8.2. Cleaning of the cell
To remove the deposits on the cell, use a special cell cleaner or contact your local retailer:
Rinse the cell and then reassemble it. If necessary, recalibrate your inversion frequency.
The lifespan of the cell is very closely linked to the respect for the instructions indicated in this user
manual). We recommended only using original cells. The use of "compatible" cells can entail a re-
duction in the production and reduce the life cycle of the device. A deterioration linked to the use of
a compatible cell cancels the contractual warranty.
9.

FAILURE DIAGNOSTIC

Security
Causes
Lack of water
Lack of salt
Cell problem
A1
Controller box
problem
Bad connection
A2
Controller box
problem
A1) Alarm is normally disabled. You can activate it, if necessary.
MV-1812-1813-11-2017 . © All rights reserved Swim & Fun Scandinavia ApS
Self-cleaning avoids the limestone deposits in the cell.
However, if the cell is nevertheless calcified,
proceed to a manual cleaning:
Turn off filtration, remove the cell and check deposit
presence on the electrodes.
Explanations/Remedies
Chlorine production is stopped.
Check full and constant flow of water in the cell.
Chlorine production is degraded or almost not existing.
Verify salt rate in the pool with your measuring kit. It has to be higher than 3 kg/m3
and ideally 5.
Chlorine production is degraded or almost not existing.
1) Verify that the cell is not scaly.
2) Verify that nuts on the terminals of the cell are well tightened and not oxidized.
3) Most of the time this code indicates that cell no longer works or are totally scaly,
and can't produce chlorine anymore. Contact your local retailer to replace it.
Chlorine production is stopped.
An electronic component in the controller box is defective.
Contact your local retailer.
Chlorine production is stopped.
Verify that nuts on the terminals of the cell are well tightened.
Chlorine production is stopped.
An electronic component in the controller box is defective.
Contact your local retailer.
61