Herunterladen Inhalt Inhalt Diese Seite drucken

For Your Safety; Delivery Contents; Device Description - Aventics EBS-PI Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
AVENTICS | EBS-PI | R412008279–BDL–001–AB | English
English
1
About this document
These instructions contain important information on the safe and appropriate
assembly and operation of the EBS-PI ejector and how to remedy simple
malfunctions yourself.
O Read these instructions completely, especially chapter 2 "For your safety" before
working with the EBS-PI ejector.
Related documents
The EBS-PI ejector is a single component. Also follow the instructions for the other
system components.
This includes:
W
Manufacturer's system documentation
Additional information on the EBS-PI ejector can be found in the online catalog from
AVENTICS at www.aventics.com/pneumatics-catalog.
Abbreviations used
Abbreviation
Meaning
EBS
Ejector
EBS-PI
Pneumatic, I design
Presentation of information
Warnings
In this document, there are warning notes before the steps whenever there is a
danger of personal injury or damage to equipment. The measures described to avoid
these hazards must be observed.
Structure of warnings
Hazard type and source
Consequences of non-observance
O Measures to avoid these hazards
Meaning of the signal words
Indicates a hazardous situation which, if not avoided, could result in minor or
moderate injuries.
Indicates damage to property: The product or its environment may be damaged.
Symbols
Operation may be impaired if this information is disregarded.
2

For your safety

The EBS-PI has been manufactured according to the accepted rules of safety and
current technology. There is, however, still a danger of personal injury or damage to
equipment if the following general safety instructions and the warnings before the
steps contained in these instructions are not complied with.
O Read these instructions completely before working with the EBS-PI.
O Keep these instructions in a location where they are accessible to all users at all
times.
O Always include these instructions when you pass the EBS-PI on to third parties.
Intended improper use
The EBS-PI is used to convert the energy of the compressed air into a vacuum.
O The EBS-PI is only intended for industrial applications.
O Observe the performance limits listed in the technical data.
Intended use includes having read and understood these instructions, especially the
chapter "For your safety".
SIGNAL WORD
CAUTION
NOTICE
Improper use
The EBS-PI may not be used to exhaust liquids, gases, or granulates.
It is considered improper use when the EBS-PI
W
is used for any application not named in these instructions,
W
is used under operating conditions that deviate from those described in these
instructions.
Personnel qualifications
Assembly, disassembly, commissioning, and operation require basic pneumatic
knowledge, as well as knowledge of the appropriate technical terms. Assembly,
disassembly, commissioning, and operation may therefore only be carried out by
qualified pneumatic personnel or an instructed person under the direction and
supervision of qualified personnel.
Qualified personnel are those who can recognize possible hazards and institute the
appropriate safety measures due to their professional training, knowledge, and
experience as well as their understanding of the relevant conditions pertaining to the
work to be done. Qualified personnel must observe the rules relevant to the subject
area.
The following must be observed
General safety instructions
O Observe the regulations for accident prevention and environmental protection for
the country where the device is used and at the workplace.
O Do not change or modify the EBS-PI.
O Only use the EBS-PI within the performance range provided in the technical data.
O Do not place any mechanical loads on the EBS-PI under any circumstances.
O Always comply with country-specific regulations.
Before assembly
O Make sure that the relevant system parts are not under pressure before you
assemble the EBS-PI.
During assembly
O Make sure that all the connections on the EBS-PI are properly connected and all
the plastic tubing is firmly fitted.
During operation
O Only use compressed air (ISO 8573-1), class 7-4-4 as the medium.
O Do not place any mechanical loads on the EBS-PI.
Disposal
Dispose of the EBS-PI in accordance with the applicable national regulations.
3
Applications
The EBS-PI generates a vacuum. Loads can then be picked up using suction grippers.
The EBS-PI is available in the following design:
Symbol
Designation
EBS-PI
1
3
2
4

Delivery contents

The following is included in the delivery contents:
EBS-PI
W
1x EBS-PI ejector
W
1x operating instructions
5

Device description

1 Compressed air
2 Connection 2: vacuum
3 Exhaust openings, both sides
Connection design
Push-in fitting
1
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis