Herunterladen Inhalt Inhalt Diese Seite drucken

Werbung

ACTIVE STAGE MONITOR
VRM-110A
VRM-112A
VRM-115A
WWW.HHELECTRONICS.COM

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für HH Electronics VECTOR VRM-110A

  • Seite 1 ACTIVE STAGE MONITOR VRM-110A VRM-112A VRM-115A WWW.HHELECTRONICS.COM...
  • Seite 2: Inhaltsverzeichnis

    CONTENTS Important Safety Instructions............ Instructions Importantes De Securite - Français....Wichtige Sicherheitshinweise - Deusch........Instrucciones Importantes Para Su Seguridad Español..Important Safety Instructions Pt 2..........Foreword..................Introduction.................. Vector Active Series Front Panel..........Vector Active Series Side Panel..........Vector Active Series Setup Diagram........Useful Hints and Tips..............
  • Seite 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electrical products, basic cautions should always be followed, including the following: 1. Read these instructions. 2. Keep these instructions safe. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6.
  • Seite 4: Instructions Importantes De Securite - Français

    INSTRUCTIONS IMPORTANTES DE SECURITE - FRANÇAIS ATTENTION: L’utilisation de tout appareil électrique doit être soumise aux precautions d’usage incluant: 1. Lire ces instructions 2. Gardez ce manuel pour de futures références. 3. Prétez attention aux messages de précautions de ce manuel. 4.
  • Seite 5: Wichtige Sicherheitshinweise - Deusch

    WICHTIGE SICHERHEITSHINWEISE - DEUSCH ACHTUNG: Beim Einsatz von Elektrogeräten müssen u.a. grundlegende Vorsichtsmaßnahmen befolgt werden:durch. 1. Lesen Sie sich diese Anweisungen 2. Bewahren Sie diese Anweisungen auf. 3. Beachten Sie alle Warnungen. 4. Befolgen Sie alle Anweisungen. 5. Setzen Sie dieses Gerät nicht in der Nähe von Wasser ein. 6.
  • Seite 6: Instrucciones Importantes Para Su Seguridad Español

    INSTRUCCIONES IMPORTANTES PARA SU SEGURIDAD - ESPAÑOL CUIDADO: Cuando use productos electrónicos, debe tomar precauciones básicas, incluyendo las siguientes: 1. Lea estas instrucciones. 2. Guarde estas instrucciones. 3. Haga caso de todos los consejos. 4. Siga todas las instrucciones. 5. No usar este aparato cerca del agua. 6.
  • Seite 7: Important Safety Instructions Pt 2

    IMPORTANT SAFETY INSTRUCTIONS PT 2 Intended to alert the user to the presence of uninsulated ‘Dangerous Voltage’ within the products enclosure that may be sufficient to constitute a risk of electrical shock to persons. Ce symbole est utililise pur indiquer a l’utilisateur de ce produit de tension non-isolee dangereuse pouvant etre d’intensite suffisante pour constituer un risque de choc electrique.
  • Seite 8: Foreword

    To register your purchase, leave your feedback and learn more about other HH products please visit us at: www.HHelectronics.com Thanks again. HH Electronics Designed and engineered with Head & Heart in the United Kingdom...
  • Seite 9: Unpacking

    INTRODUCTION The Vector range of active monitors has been designed and voiced specifically for all stage monitoring applications including electric and acoustic instruments, vocals and drums, and for DJ use. Cabinets, horns, drive units and crossovers have been optimised to provide clarity and detail in a focused field. Simple but effective controls allow intuitive adjustment of the powerful amplifier stages.
  • Seite 10: Vector Active Series Front Panel

    VECTOR ACTIVE SERIES FRONT PANEL VECTOR ACTIVE SERIES FRONT PANEL 1. COMBI INPUT: A line level balanced input compatible with balanced and unbalanced XLR and jack signal leads. Note; as this is a balanced input, a stereo signal cannot be connected to this socket.
  • Seite 11: Vector Active Series Side Panel

    VECTOR ACTIVE SERIES SIDE PANEL VECTOR ACTIVE SERIES SIDE PANEL 1. MAINS INLET IEC input for connection of an appropriate mains lead. 2. FUSE The main fuse is located at the top of the IEC socket. In case of failure replace only with the type and rating specified on the panel.
  • Seite 12: Vector Active Series Setup Diagram

    VECTOR ACTIVE SERIES SETUP DIAGRAM VECTOR ACTIVE SERIES SETUP DIAGRAM Line level signals can be connected to the input using a balanced or unbalanced XLR or a 6.3mm jack. The input signal can be supplied to another device through a Male XLR in the Link Output socket. Passive (8 ) extension monitors can be connected via Ω...
  • Seite 13: Useful Hints And Tips

    USEFUL HINTS AND TIPS USEFUL HINTS AND TIPS All speakers should be balanced and steady. If stacked strap them together to Ÿ improve stability. Don't overextend poles/tripods; ensure at least 4 x the pole diameter is still inside Ÿ the outer pole. Make sure the legs have a good splay on tripods, but do not obstruct doorways or Ÿ...
  • Seite 14: Block Diagram

    BLOCK DIAGRAM...
  • Seite 15: Specifications

    SPECIFICATIONS VRM-110A VRM-112A VRM-115A 4 Ohm power 250W RMS 120W RMS Frequency 65Hz-20kHz 76Hz-20kHz Response Sensitivity 97dB 97dB 96dB (1W@1m) 116dB (standalone) 119dB (standalone) 118dB (standalone) Max SPL 120.5dB (with VRM-110 124dB (with VRM-112 123dB (with VRM-115 (calculated) extension) extension) extension) Output Circuitry Class AB...
  • Seite 16 WEEE (Waste Electrical and Electronic Equipment) directive applicable in your country. In the interest of continued development, HH Electronics reserves the right to amend product specification without prior notification. Trademarks: Speakon and the names of Neutrik®AG products...
  • Seite 17: Connector Wiring

    CONNECTOR WIRING Balanced XLR 1 GROUND 2 HOT 3 COLD 6.3mm Balanced Jack RING COLD SLEEVE GROUND 6.3mm Unbalanced Jack SLEEVE GROUND Speakon ™ 1+ POSITIVE 1- NEGATIVE 2+ NOT USED 2- NOT USED...
  • Seite 18: Notes

    NOTES...
  • Seite 19 NOTES...

Diese Anleitung auch für:

Vector vrm-112aVector vrm-115a

Inhaltsverzeichnis