Herunterladen Diese Seite drucken

Balluff BUS D50K9-XA-03/100-EP00 Bedienungsanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BUS D50K9-XA-03/100-EP00,3-GS04
Ultrasonic Level Sensor
Installation
Two screw bosses are required to fix the sensor at the
desired measurement position on the container bottom on
an even surface.
The screw bosses must have the following dimensions:
Thread
Spacing of the screw bosses
Height of the screw bosses
To fix the sensor, the mounting holes on the sensor are
inserted in the screw bosses so that the flexible measuring
diaphragm faces the container bottom. Next, the sensor is
screwed evenly so that an even pressure is applied to the
measuring diaphragm. The torque for both nuts with the
corresponding washers must not exceed 1 Nm.
Pin
1
2
3
4
Signal 0 to 10 V DC
Top view of the plug
www.balluff.com
M3.5
55 ±0.3 mm
Approx. 25 mm
Signal
24 V DC
Not used
GND
Technical data and requirements
Housing material
Operating temperature
Storage temperature
Degree of protection per
IEC 60529 when plug is
attached
Cable with connector
Cable
Wire cross-section
Cable coating material
Cable length
Technical measurement data
Information refers to the measuring medium of water
(static)
Measuring range of fill level through
≤ 5 mm plastic (not fiber reinforced)
Measuring accuracy of display value ±3%
Measuring frequency
Time to first measured value
Electric data
Ub
Max. current draw at 24 V DC
Analog output load current (PIN 4)
Protect plug contacts from contact (ESD) and
contamination.
Balluff GmbH
Schurwaldstraße 9
73765 Neuhausen a.d.F.
Germany
Telephone +49 7158 173-0
Fax +49 7158 5010
Service Center +49 7158 173-370
service@balluff.de
PPS
−35°C...+80°C
−40°C...+100°C
IP67
3 wire
0.34 mm
2
PUR
300 mm
40...1000 mm
10 Hz
≤ 3 s
24 V DC
(20...28 V DC)
30 mA
≤ 5 mA
english
2

Werbung

loading

Diese Anleitung auch für:

Bus 3-gs04