Herunterladen Diese Seite drucken

HANSGROHE Metropol Select 100 32570003 Gebrauchsanleitung, Montageanleitung Seite 3

Vorschau ausblenden Andere Handbücher für Metropol Select 100 32570003:

Werbung

Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Instantaneous heater didn't work
Valve stiff / leaking
English
Cause
- Supply pressure inadequate
- Filters are dirty
- Backflow preventers dirty or
leaking
- Filters are dirty
- check valve hasn't moved back
- Supply pressure inadequate
- Select stop valve damaged /
soiled
- Temperature limiter plugged on
improperly
Assembly (see page 6)
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean the filter / exchange filter
- Clean backflow preventers,
exchange if necessary
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Exchange Select stop valve
- Plug on the temperature limiter
once more (see page 8)
3

Werbung

loading