INsTALLATIoN

Appliance compatibility

WARNING Injury
!
f For safety reasons, only operate the appliance with
f
the casing closed.
2.3

Test symbols

See type plate on the appliance.
3.
Appliance compatibility
The appliance can be operated in conjunction with the following
air source heat pumps:
- WPL 13/18/23 E
- WPL 13/18/23 cool
- WPL 19/24
4.

Appliance description

The compact function module enables easy, neat connection of the
air ducts to the external walls. The buffer cylinder charging pump,
DHW charging pump and heat pump manager are already built
in and pre-installed. An emergency/booster heater is integrated
into the module.
28
| WPIC
INsTALLATIoN
5.

Safety

Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
5.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
5.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
6.
Appliance description
The heating circuit pump and a three-way valve for changeover
between the heating circuit and the DHW circuit are part of the
function module. To heat DHW, the heating water that has been
heated by the heat pump is pumped through an indirect coil in the
DHW cylinder, where it transfers its energy to the DHW.
Air hoses are fitted to the function module for connection to the
air intake and air discharge openings in the wall.
The function module and heat pump are controlled by an integral,
weather-compensated return temperature controller (WPM heat
pump manager).
6.1

Standard delivery

Delivered with the function module:
- 1 x Heat pump casing sections
- 2 x Air guide hose
- 1 x Outside sensor AF PT
- 2 x TAF PT immersion/contact sensor
- 1 x Insulating mat
- 2 x Insulation section for circulation pump
Connection accessories
- 2 x Pressure hose
www.stiebel-eltron.com