Herunterladen Diese Seite drucken

AIRFORCE F205 90 TSE Montage- Und Gebrauchsanweisung Seite 20

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
I
AVVERTENZE
WARNINGS
Ensure there is an electricity mains access point near the hood and
that the system has a 30 mA differential switch. The mains voltage
must correspond to the voltage on the characteristics label inside the
hood. The hood is equipped with an electricity cable measuring 1250
mm long with or without a plug: if with a plug, connect the hood to a
socket compliant with standards in force placed in an accessible zone.
If without (connect directly to the mains), apply a device that ensures
omnipolar disconnection from the mains, with an opening distance
of the contacts that allows complete disconnection of category III
overvoltage.
If the cooking top is in use, the cooker hood must always operate.
Product performance test carried out in accordance with standard
(EU) No 65/2014-Ref: IEC 61591
Maximum performance is achieved by placing the mobile panels, if
any, in the open position.
Any presses or shelves beside the hood must be installed at least 1 mm
from the product.
For correct extraction, you are advised to dimension the hob based on
the dimension of the hood.
For example:
60cm hood for a 60cm hob (up to 4 burners)
90cm hood for a 78cm hob (up to 5 burners)
90cm hood for a 90cm hob (up to 6 burners)
20

Werbung

loading

Diese Anleitung auch für:

F206 tse