19.4 Load balancer
If you want to install the charging station in combination with a load
balancer you must connect it to the charging station in the following way.
The installation instruction of the charging station in the fuse box can be
found in the manual of the load balancer itself.
The data cable from the load balancer must be connected to the gray clip
(see drawing).
20. MAINTENANCE
Always disconnect the charging station from the power supply
and read the manual before performing maintenance or fixing
a malfunction.
Only products approved by the supplier can be used to repair or replace
components. Repairs and replacements should always be carried out by a
certified specialist.
Maintenance should always comply with and be carried out in accordance
with NEN3140 and NEN50110 low voltage EU regulations.
Check the charging station for leaks.
Check the connection of the main power cable and ensure a tight
connection, see point 19.3
Treat any damage to the charging station with anti-corrosion paint.
21. TRANSPORTATION AND STORAGE
Transport the charging station (technical core) upright and prevent the paint
from being damaged, as this could cause rust.
The covers may be transported in various ways as long as they are protected
from damage. Preferably store the charging station in a dry, non-humid
space.
When hoisting the charging station into position, there are 4 securing holes
for lifting eyes on the top of each corner of the charging station. The top
cover must first be removed for this purpose. The lifting eyes can be removed
after fitting. To ensure a safe work setting, only a certified fitter may hoist the
charging station.
21