FUNCTION
SuperSimplex monitors the pressure that exists inside the pip-
ing and the presence of flow. At the minimal pressure P(r), set up
for the system, the SuperSimplex activates the pump.
The flow gauge inside the SuperSimplex keeps the pump in
operation; when the water collection operation is over and with
maximum pressure, SuperSimplex acts to disenable the pump
with delay of a few seconds.
Warning: it does not cut the max pressure of the pump.
Problem
Case 1. Retardant malfunction:
The pump
fails to
Case 2. the re-start pressure P(r) is set
disconnect with
too high, in relation to the pump head.
the taps
Case 3. air in the system
closed
Case 4. check for the presence of water
Case 5. flow valve blocked (*) due to the
presence of waste particles
Case 1. The re-start pressure P(r) is set
too low
The pump
fails to
Case 2. The plant pressure with open
engage with
taps is greater than the re-start pressure
the user
P(r) that can be set.
point open
Case 3. No Power Supply
Case 4. Pump blocked due to lack of
water. Check that water is present.
Flow reduction
Input filter blocked
Problem
The pump does
not disconnect
with closet taps
Insufficient water
Led on, although
water is
present
The pump fails to
engage with user
point open, pump
led off, and "lack
of water" led off
Water fails to
arrive with user
points open,
pump led on
No led on
Diagnosis
Diagnosis
Case 1. flow valve blocked (*) due to the
presence of waste particles
Case 2. the "Service" button has
remained pressed.
Case 1. the re-start pressure P(r) is set
too high, in relation to the pump head.
Case 2. air inside the plant
Case 3. Retardant malfunction:
Case 4. System awaiting automatic
re-start.
Case 5. Input filter blocked
Case 1. The re-start pressure P(r) set too
low
Case 2. Pressure of the plant with taps
open greater than the max. restart
pressure P(r) that can be set.
Pump incorrectly connected to the
terminal board.
Check the electrical connection of the device and for the presence of any electricity supply.
8
Normal operation, once completed the installation: pump is ON
with tap open and OFF with tap closed.
Led for SSE:
Pump ON →
Pump ON →
Presence of water →
Solution SuperSimplex M
Clean the retardant device (see instructions entitled "Retardant
cleaning"). If the problems persists make some incisions with a sharp
blade on the upper surface of the retardant device.
Reduce it by loosening the knob (see instructions entitled "installation")
Open a tap to discharge the system.
Install a protective float, against dry running.
Check the conditions and clean the valve and its slot (see instructions
"Cleaning the flow valve")
Turn the knob in a clockwise sense when the pump engages, check that
the pump disconnects with null use, if it fails to disconnect it means that
the head supplied by the electropump is insufficient for the required
performance levels.
The device is installed with water column > 20mt. Not compatible
Check the electrical connection of the device and for the presence of any
electricity supply.
Verify presence of water
Clean the filter (see instructions "Cleaning Filter")
Solution SuperSimplex E
Check the conditions and clean the valve and its slot (see
instructions "Cleaning the flow valve" )
Unblock the "Service" button.
Reduce it by loosening the knob (see instructions entitled
"installation")
Open the tap, press the "Service" key to discharge any air from
the plant.
Clean the retardant device (see instructions entitled "Retardant
cleaning"). If the problems persists make some incisions with a
sharp blade on the upper surface of the retardant device.
Operate manually with service key.
Clean the filter (see instructions "Cleaning Filter")
Increase by tightening the knob (see instructions under
"installation").
The device is installed with water column > 20mt. Not
compatible
Power Supply ON →
Pump OFF →
Presence of water →