Measurement method
Thickness scale
Sampling
Range of measurement
Accuracy of measurement
Measurement resolution
Minimum diameter of measurement area
Minimum system and hardware requirements for the NexPTG mobile application
Android: telephone, tablet
iOS: telephone, tablet
Android Wear: Smartwatch
1
does not apply to Economic and Economic Plus models
Electrical / measurement specification of the device NexPTG
Android 4.3 or higher,
Bluetooth with Bluetooth Low Energy support
System iOS 8 or higher, iPhone 5s or higher
Any smartwatch with this system
Magnetic induction / eddy current method
(steel, galvanized steel / aluminum
μm / mils
10 / s
0 - 1000 μm (0 – 39.37 mils) Economic, Economic Plus and
Standard models
0 - 2200 μm (0 – 86.61 mils) Advanced model
0 - 2500 μm (0 – 98.43 mils) Professional model
2% - device accuracy
5% - accuracy of the calibration set
10 μm (0.4 mils) Economic, Economic Plus, Standard models
1 μm (0.04 mils) Advanced and Professional models
20mm