Herunterladen Inhalt Inhalt Diese Seite drucken

Lamborghini Caloreclima FIME 5 S-E Betriebs-Anleitung Seite 34

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 52
PRESSURE CURVES - GAS DELIVERY - B/P
16
14
12
10
8
6
4
2
0,5
0,75
10
20
14
21
Thermal output
EXTERNAL AIR INTAKE KIT ASSEMBLY
Bails
3
2
Flexible hose (max 3 m)
MAINTENANCE
Once a year ask to qualified personnel the following:
- checking of the internal tightness of the valves;
- filter cleaning;
- fan and head cleaning;
- checking of the ignition electrodes and control probe adjustment;
- gas and air pressure switches adjustment;
- combustion test, by taking CO2, CO, smoke temperature (TF) figures
- checking of all gaskets tightness.
ATTENTION:
In the event of repair or disassembly/assembly of the fan, check that the latter
does not touch the motor support (see enclosed information).
1
1,25
1,5
m
/h
3
30
kcal/h x 10
28
35
42
kW
Wind terminal
1
Rigid pipe diam. Ø 60
Legend
Pi Inlet pressure (combustion head + gas train)
3
Pt Pressure at combustion head
- 34
-
0,8 ÷ 1,5 mm.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fime 5 s-e-at

Inhaltsverzeichnis