FIME 5 S-E-AT
EC
1
2
MA
WARNING:
- Do not invert neutral and phase
- Make the connection to an efficient earthing system.
- The electrical power line to the burner must be fitted with an omnipolar switch with an opening of at least 3 mm between
the contacts.
- The earth connection to the terminal board of the burner must be made with a cable at least 20 mm longer than the phase
and neutral cables.
- Install with good technique and scrupulously observe the local regulations in force.
Line 230V/50Hz
L
N
S
IG
F
TS
L1
N
T1
T2
S3
B4
MB
C
PA
VS
TR
VP
2
3
4
5
6
7
8
9 10
FA
PG
11 12 31 32
- 28
-
Legend
C
Motor capacitor
EC
Control probe
F
Fuse
FA
Interference filter
IG
Main switch
MB
Burner motor
MA
Control box terminal strip
PA
Air pressure switch
PG
Gas pressure switch
S
Safety (if necessary)
TR
Transformer
TS
Safety thermostat
VP
Main safety valve
VS
2nd safety valve