Upper humidity threshold
Antifreeze temperature threshold
Technical parameters
Properties
Living room
Temperature gap
C
Antifreeze temperature threshold
Properties
D
Algorithm :
6
Diff
DT :
Properties
E
OFF
ON
F
1 h
4
5
7
PI
Set-point
+ differential
Set-point
ON
Set-point
– differential
Time
Use arrows to scroll the zone's properties.
Set the antifreeze temperature threshold
The default factory settings require that the heating system
has a minimum room temperature of 3.0 degrees Celsius,
to protect the water pipes from freezing; this minimum tem-
perature must be ensured even when the thermostat is de-
activated.
Use buttons to set the required value for the antifreeze func-
tions.
Configuring a zone's thermal parameters
You can choose between two different algorithms for con-
trolling a zone's temperature:
-
Differential Thermal Control
6
-
Proportional Integral control
7
When you choose the thermal differential algorithm, use the
buttons to set the required differential value.
The range of settings is between 0 and 2 degrees
Celsius.
The thermal differential algorithm is suitable for rooms that
are hard to warm, where there are extreme fluctuations in
exterior temperatures. It controls the powering up of the sys-
tem, as shown in illustration F.
.
4
.
5