Notes:
Bin full light will be ON when the control senses a height of ice that is more than it is set
for. A cubed ice machine might make another batch of ice after sensing that the bin is full.
To adjust: Rotate knob so the arrow points to the desired position.
To override: Rotate knob to the Off or Max position (arrow-to-arrow). The machine will
make ice until the curtain switch stays open (cubers) or electric eye blocked (nugget/
flaker).
Note: When used with the Smart-Board, and its 7 Day Programmable Ice Level feature is
engaged, the adjustment knob of the Vari-Smart will not have any affect on ice level.
Cuber on Countertop ice dispensers: Set control to the 9 position (first click CW from
arrow-to-arrow). At this setting the control will maintain a lowered level of ice that might
occasionally be high enough that the ice machine will shut off on the curtain switch. This
is normal. The average level of ice will be significantly lower than if the control was not
being used. Models C0830 and C1030 may shut off after a few cycles due to their tall ice
slab. Dispensing or agitation of ice will restart the machine.
Nugget Ice Machines on Ice Dispenser: Set control to the 14 position (7th click CW
after arrow-to-arrow position), adjust as needed between 9 and 14 (1 to 7 clicks).
Important note: To achieve trouble-free nugget ice dispensing, it is extremely important
that all the nugget ice kits are all install properly. There are also some dispensing settings
that are required to be adjusted. Off cycle agitation needs to be minimized. Typical
settings: 1/2 second ON time with 3 hours of OFF time. If agitation cannot be adjusted
NO agitation is recommended.
Mineral deposits in dispensers will affect nugget ice dispensability. If you are reusing an
older dispenser it is important to ensure that all interior and ice chute surfaces are clean
and free of any mineral.
For additional information please contact tech support at 1-800-533-6006
Note: Do NOT adjust lower (higher position number) than 15 when the ice machine is on a
dispenser. Adjusting ice lower than position 15 will result in an empty dispenser.
Ice storage bins: Set the control to any desired position.