Adjust the knob in half-turn increments to approach 10°F (screw in to reduce/unscrew to increase).
Note: It is recommended that the residual TH be checked every 3 months, and any drift should be corrected.
X.

SERVICING

Items required:
- Recharging salts,
- Water hardness testers,
- A cleaning product for the water softener.
WHEN IS SERVICING REQUIRED?
The water softener should be regularly serviced in order to ensure that the salt supply is sufficient for operation, to
prevent bacteriological infection of the softened water and to ensure that the water softener operates properly
throughout its life cycle.
If the water softener is not used for more than 10 days, it should be cleaned using a suitable product.
ELEMENTS THAT NEED SERVICING
The salt box: Check that the salt reserve is sufficient for the proper operation of the water softener.
The resin cylinder can be affected by bacteria that prevent the resins from acting effectively and are dangerous for
water consumption.
The recharge programmer: Check that the clock is properly set.
SERVICING ACTIONS
· Every 3 months, check the salt reserve (must not fall below 1/3 of the box depth). The brine must never be visible
above the salt. Also check the clock setting and the hardness of the water delivered by the softener, which should be
between 7° and 12° TH.
· Every 6 months, check the filter clogging and change the cartridge if necessary.
· Every 6 months or following a long period without use, pour a dose of antiseptic cleaning product into the water
softener and then run a manual recharge, before restarting the water softener.
- Unlock the screen by pressing the
- When the screen is unlocked, press the
Recharging will last around 45 mins. Run all the recharge cycles.
Note: During the recharge, check that none of the connections/unions are leaking. If significant leaking is observed,
close the mains water supply until corrective action has been taken.
· Annually, carry out a complete water softener servicing operation.
and
keys together.
key to start the recharge.