VIII.

STARTING WATER SOFTENER OPERATION

When the water softener has been properly set up, as described above, it can start softening water.
OPEN THE MAINS WATER SUPPLY TAP
DRAIN THE AIR FROM THE SYSTEM BY OPENING A TAP SLOWLY (in the bathroom, for example).
1/ Shovel 25 kg of salt into the salt compartment. Salt used must meet the requirements of European standard EN
973.
2/ Use a bucket to pour 10 litres of water into the salt compartment.
3/ ESSENTIAL: Start the first manual recharge, in order to remove the resins from the water softener.
a. Unlock the screen by pressing the
b. When the screen is unlocked, press the
Recharging will last around 45 mins. Run all the recharge cycles.
Note: During the recharge, check that none of the connections/unions are leaking. If significant leaking is observed,
close the mains water supply until corrective action has been taken.
IX.

ADJUSTING THE MIXING

A brass screw is provided on the front of the head for fine adjustment of the residual water hardness (hardness of
water delivered by the water softener).
It is not recommended that your system water be softened to 0°F.
It is important to obtain a TH value close to, but not below, 10°F.
To adjust water hardness, unscrew (anti-clockwise) the knob to increase the TH value. It is recommended that this
adjustment be set in several steps. The more accurate the setting, the more effective and controlled the treatment.
-
Screw the knob fully in.
-
Unscrew 3 turns.
-
Measure water hardness using TH test strips or a reagent (not supplied).
and
keys together.
key to start the recharge.