INSTALLING THE WATER SUPPLY AND OUTLET

IMPORTANT: Install the water softener on the cold water system (5°C to 20°C).
IMPORTANT: Upstream of the water softener, install the following (in sequence):
-
An unsoftened cold water pipe to supply the kitchen tap (not supplied).
-
A shut-off valve (not supplied).
-
A standard isolator (not supplied).
-
A new filter with a rating of 20 to 80 µm (not supplied). Change the cartridge (not supplied) regularly,
in accordance with the manufacturer's instructions.
-
A bypass (recommended) (not supplied).
-
Downstream of the water softener, install a shut-off valve (not supplied).
Install these recommended accessories using standard unions.
CONNECTING THE WATER SOFTENER HEAD :
-
First, install the bypass on the water softener head.
BYPASS POSITION (to
isolate the unit)
Push the piston fully home
on the left-hand side.
Position the bypass at the rear of the head.
When the bypass is pushed fully home, insert both mounting
clamps in the slots provided.
Ensure that these mounting clamps are correctly installed before
filling the unit.
BYPASS OPERATION
23
SOFTENER POSITION
Push the piston fully home
on the right-hand side.
RI820165 - 07/13 - ind. B