TROUBLESHOOTING (continued)
ANTI-MOLD WASABI CASSETTE
• Anti-mold elements with wasabi aroma prevents mold growth inside the dust box in which the dust collected
by filter cleaning operation is kept. Although only a trace amount of anti-mold elements is released, there
may be wasabi smell in the room depending on the environment in which the air conditioner is used. If
you feel this smell is unpleasant, block one of the anti-mold element outlets with a commercially available
adhesive tape. If this measure is taken, the amount of anti-mold element to be released will be reduced and
the anti-mold effect will also be less accordingly. To prevent mold growth, frequent cleaning of the dust box
is recommended.
Dust box
Anti-mold
wasabi cassette
PLEASE CHECK THE FOLLOWING BEFORE SERVICE
Signal cannot be
• Do the batteries need replacement?
received
(Remote controller
• Is the polarity of the inserted batteries correct?
display is dim or
blank)
• Is the fuse blown out or circuit breaker tripped?
Operation does not
start
• Is there a blackout? (Operation remains idle after a blackout.)
• Is the micro mesh stainless filter blocked with dust?
• Is the set temperature suitable?
Does not cool well
• Have the horizontal air deflector been adjusted to the correct positions according to
Does not heat well
• Are the air inlets and air outlets of indoor and outdoor units blocked?
• Is the fan speed "LOW" or "SILENT"?
(CLEAN) indicator
• Check "filter cleaning operation".
blinks
the operation mode selected?
– 17 –
Outlet (2 places)
The gap made on
the side surface
Block one of the outlets with
an adhesive tape (Either one
of 2 outlets)