Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages; Factory Settings - OJ Electronics EuroStat Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EuroStat
Temperature scale
Allows you to set the temperature range
within which the thermostat can be set. It is
then only possible to set a temperature within
this range in auto, comfort and manual mode.
Press OK to highlight Min temperature. Use
the up or down button to select the minimum permissible tempera-
ture. Press OK and select the maximum permissible temperature.
Confirm the settings with OK.
Display illumination
There are three settings for the display back-
lighting:
• Auto: Backlighting is activated whenever a
key is pressed and goes out automatically
30 seconds after the last key press.
• On: Backlighting continuously on.
• Heating active: Backlighting comes on when heat is called for by
the thermostat.
Select the desired backlighting setting and confirm with OK.
Selecting the sensor
Floor sensors other than the supplied
(12 kΩ/ 25 °C) can be selected with this
menu. The thermostat is preprogrammed for
4 other types:
Sensor
2 kΩ
Sensor 10 kΩ
Sensor 15 kΩ
Sensor 33 kΩ
Select the installed sensor with the arrow keys, then confirm with
OK. The resistance characteristics of the sensor for 15 °C, 20 °C,
25 °C and 30 °C are now displayed.
If the installed sensor does not have the same characteristic as
that shown in the thermostat display, change the values at the four
listed temperatures using the arrow keys.
Confirm with OK to switch to the next resistance characteristic.
Select Information with the arrow keys, then confirm with OK.
The display now shows the resistance characteristic of the selected
sensor. Then confirm with OK. The new sensor values are now
stored in the thermostat.
NB! If the incorrect sensor is selected there is a risk that the ther-
mostat will not be able to regulate to the desired temperatures and
therefore damage to the floor construction or covering may occur.
Language
Allows the language used on the display to
be changed.
Press OK and select the required language.
Confirm with OK.
4
Factory reset
Allows factory settings to be restored. Your
personal settings will be lost, see Factory
Temp scale
settings.
Press OK and choose Reset in the menu.
OK
Confirm with OK.
Information
Displays the thermostat software version.
Back
In various parts of the menus and submenus
you will find the Back menu item.
Backlight
Use Back to return to the last step.
OK
Exit
Returns to initial dispay.

Error messages

If a fault or error occurs, the thermostat will display an error code as
follows:
E0: Internal failure. The thermostat is defective. Replace thermostat.
E1: Internal sensor defective or short-circuited.
Sensor
E2: External sensor defective or short-circuited.
E5: Internal overheating. Inspect the installation.
OK

Factory settings

Preset schedule
Day 1-5
Event
Day
Out
Home
Night
Day 6-7
Event
Day
Night
Language
OK
© 2012 OJ Electronics A/S
Time
With floor sensor With room sensor
06:00-08:00
25 °C
08:00-20:00
18 °C
20:00-23:00
25 °C
23:00-06:00
18 °C
Time
With floor sensor With room sensor
08:00-23:00
25 °C
23:00-08:00
18 °C
English
Factory reset
OK
Information
OK
20 °C
13 °C
20 °C
13 °C
20 °C
13

Werbung