User settings
In the user settings menu you can change the
following items:
• Time and date
• Child lock
• Display settings
• Event schedule
• Energy monitor
Time and date
Press OK and set the actual time in hours
and minutes.
The date will then be displayed. Set the date
and confirm with OK.
Child lock
Allows you to lock the thermostat settings,
e.g. in public or other places where you do
not want the settings changed.
Press OK and set the child lock to On using
the down button. Confirm with OK.
The child lock can be unlocked by pressing both the Comfort and
Manual buttons simultaneously for 5 seconds.
Display settings
Allows you to select what is shown on the
initial display.
Time/day: Shows the actual time and day at
the top of the display.
Set temp.: Shows the current temperature
setting.
Act. temp.: Shows the actual measured temperature.
Scr. saver: Switches off the display after 30 seconds if no button is
pressed. Any subsequent press of a button reactivates
the display. The thermostat remains on and runs the
selected program.
Press the OK button to select or deselect the display options. Then
select Exit in the menu to return to the initial display and view your
chosen settings.
Event schedule
Allows you to choose the type of weekly
event schedule you require.
4-event:
5:2 : Monday to Friday with 4 events and
Saturday to Sunday with 2 events.
Typically used if you work from Monday to Friday.
6:1 : Monday to Saturday with 4 events and Sunday with 2 events.
Typically used if you work from Monday to Saturday.
7:0 : Monday to Sunday with 4 individual events. Allows you to
choose individual programs for each of the 7 days of week.
6-event:
5:2 : Monday to Friday with 6 events and Saturday
and Sunday with 2 events. Typically used if you
work from Monday to Friday.
6:1 : Monday to Saturday with 6 events and Sunday
with 2 events. Typically used if you work from
Monday to Saturday.
7:0 : Monday to Sunday with 6 events. This allows
you to choose individual programs for each day
of the week.
0:7 : Monday to Sunday with 6 events and the same
program for all days of the week.
Select the required event schedule and confirm with OK.
For instructions on programming the time and temperature for the
User settings
event schedule, see Event settings.
OK
Energy monitor
Allows you to view energy consumption for
the past 2 days, 30 days or 365 days.
Press OK for the chosen period. The value
in per cent (%) shows the relative amount of
time the heating has been on. The following
figure is the cost for the selected period. To ensure correct calcula-
Time and date
tion, check the settings for currency, price per kWh and load.
Currency: Press OK and chose the required currency.
OK
Cost/unit: Press OK and set the actual cost of electricity.
Load:
Child lock
OK
Engineer settings
The Engineer settings menu contains the
following options:
• Offset temperature
• Adaptive function
Display settings
• Application
• Temperature scale
OK
• Display illumination
• Selecting the sensor
• Language
• Factory reset
• Information
Offset temperature
If the actual measured temperature does not
corresponding to the thermostat value, you
can adjust the thermostat by offsetting the
temperature.
Press OK and enter the value of the measu-
red temperature. Confirm with OK.
Adaptive function
Event schedule
Ensures that the required temperature has
OK
already been reached when you get up in the
morning or come home from work. After just
a few days, the adaptive function will have
automatically calculated when the heating
must be turned on.
Press OK and set the function to On. Confirm with OK.
Application
Set the type of regulation used.
There are 4 options:
Floor reg. :
Room reg. : The thermostat regulates room temperature only.
Room/limit : The thermostat regulates room temperature with min.
Regulator :
Press OK and select the required application. Confirm with OK.
© 2012 OJ Electronics A/S
Confirm with OK.
The cost must be entered per kWh. Press OK.
Press OK and enter the connected heating power.
The value must be in watt (W). Press OK.
Leave the menu by pressing Exit.
The thermostat regulates floor
temperature only. A floor sen-
sor must be connected.
and max. limits for floor temperature. A floor sensor
must be connected.
The thermostat functions as a simple regulator and no
sensors are used. The setting is a percentage.
English
Energy monitor
OK
Engineer settings
OK
Offset temp.
OK
Adaptive function