APPLICATION
The ignition switch Q640 is designed to operate an ignition
transformer or a main switch between line and ignition
transformer, which ignites the pilot burner during the ligth up
sequence of the appliance.
The ignition switch Q640 is for use with the V4600/V8600
series gas controls.
SPECIFICATIONS
Model
Q640A 1002 packing quantity 100 pcs
Q640A 1010 as Q640A 1002 except TRADELINE (single
pack in a box of ten pieces).
Max. ambient temperature
Ignition switch: 70 _C
Lead wire: 105 _C
Electrical rating
1.5 A at 220 Vac inductive load.
Length of lead wire
2 x 50 cm
Srain relief
70 N minimum
INSTALLATION
IMPORTANT
The ignition switch can only be mounted at the inlet
side of the V4600/V8600 series gas controls.
Mounting (See fig. 1.)
· Insert the plunger of the ignition switch under the retainer
of the knob of the gas control.
· Fix the ignition switch with the M3.5 x 6 screw.
Wiring
The ignition switch is double insulated, therefore no earthing
is needed when the ignition switch is mounted on a low
voltage gas control.
Connect the lead wires of the ignition switch according to the
manufacturer's instructions.
Operation
The plunger of the ignition switch will be pushed down by
means of the knob during the ligth--up sequence of the
appliance.
A return spring under the plunger pushes back the plunger to
its ready position when the knob of the gas control is
released.
Checkout
Before leaving, set the appliance in operation and observe
through a complete cycle to ensure that the burner system
components function correctly.
Q640
IGNITION SWITCH
INSTRUCTION SHEET
Fig. 1.
MU1R--9176 0002R0--NE

Werbung

loading

Inhaltszusammenfassung für Honeywell Q640

  • Seite 1 APPLICATION manufacturer’s instructions. Operation The ignition switch Q640 is designed to operate an ignition The plunger of the ignition switch will be pushed down by transformer or a main switch between line and ignition means of the knob during the ligth--up sequence of the transformer, which ignites the pilot burner during the ligth up appliance.
  • Seite 2 Zündbrenner während der Zündund des Geräts gezündet angebracht werden. wird. Einbau (siehe Abb. 1.) Der Zündschalter Q640 ist für den Einsatz mit den · Setzen Sie den Kolben des Zündschalters unter der Gas--Regelventile der Serie V4600/V8600 bestimmt. Halterung des Knopfs des Gas--Regelventils ein.
  • Seite 3 ITALIANO Q640 INTERRUTTORE DI ACCENSIONE APPLICAZIONE INSTALLAZIONE L’interruttore di accensione Q640 è progettato per attivare un IMPORTANTE trasformatore di accensione o un interruttore principale tra la L’interruttore di accensione può essere montato linea e il trasformatore di accensione, che accende unicamente sul lato di ingresso dei dispositivi di l’accenditoio durante la sequenza di accensione del...
  • Seite 4 FRANÇAIS Q640 INTERRUPTEUR D’ALLUMAGE APPLICATION MONTAGE L’interrupteur d’allumage Q640 est conçu pour la commande IMPORTANT d’un transformateur d’allumage ou d’un interrupteur général L’interrupteur d’allumage peut être monté entre la ligne et le transformateur d’allumage, qui allume le uniquement sur le côté d’entrée des dispositifs de brûleur pilote au cours de la séquence d’allumage de...